Skip to main content
Siemens 3VA2116-7HN32-0AA0 — Molded Case Circuit Breakers (MCCB)

3VA2116-7HN32-0AA0 SENTRON MCCB, 160 A, 3-Pole, ETU350, 330

MPN3VA2116-7HN32-0AA0
Active

Siemens SENTRON 3VA2116-7HN32-0AA0, 3-pole molded case circuit breaker, 160 A continuous, ETU350 electronic trip unit, 330 kA breaking capacity at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-7HN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2116-7HN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-7HN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-7HN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-7HN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2116-7HN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-7HN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries and where it fits

The Siemens SENTRON 3VA2116-7HN32-0AA0 is a 3-pole molded case circuit breaker rated for 160 A continuous current, using the ETU350 electronic trip unit for adjustable overload and short-circuit protection. It's designed for line protection — meaning it sits at the feeder or main distribution point in a panel, not as a motor-protective device. The 800 V rated insulation voltage gives headroom for 480 V and 600 V class systems without derating the insulation boundary.

Breaking capacity — what the numbers mean for fault duty

The interrupting ratings span the common industrial voltages: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. That 330 kA at 240 V is a very high interrupting capacity — it handles large transformer-fed faults common in North American 240 V delta services. The drop to 3.7 kA at 690 V is typical for this frame size; if your system runs 690 V with high available fault current, you need to verify coordination upstream. The ETU350 trip unit lets you set the short-time pickup and delay for selective coordination with downstream breakers.

Thermal performance and panel integration

The 160 A rating holds flat from 40 °C through 70 °C ambient — no derating needed across that range, which simplifies panel layout in warm enclosures. Maximum power loss is 25.5 W, so factor that into your thermal budget if the MCCB shares a small enclosure with other heat sources. The front face carries IP40 protection; the rest of the breaker relies on the enclosure's IP rating. Dimensions are 105 mm wide, 181 mm high, 86 mm deep — standard 3-pole MCCB footprint for DIN-rail or panel-mount installation.

Frequently asked questions

What is the breaking capacity of this MCCB at 240 V?

330 kA at 240 V. That's the highest interrupting rating on this frame, suited for high-fault locations like transformer secondaries.

What trip unit does the 3VA2116-7HN32-0AA0 use?

The ETU350 electronic trip unit. It provides adjustable overload pickup, short-time delay, and instantaneous settings for selective coordination.

Where can I buy 3VA2116-7HN32-0AA0 and how is it quoted?

Sourced through independent industrial automation distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

MPN
3VA2116-7HN32-0AA0