Siemens 3VA2116-7KP42-0AA0 SENTRON MCCB, 160 A, 4-Pole, ETU8

MPN3VA2116-7KP42-0AA0
Active

Siemens SENTRON 3VA2 series, Molded case circuit breaker, 3VA2116-7KP42-0AA0, 4-pole, 160 A rated continuous current, ETU850 electronic overcurrent release, line protection version, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-7KP42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2116-7KP42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.8 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-7KP42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850

Construction & Connection

3VA2116-7KP42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-7KP42-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2116-7KP42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-7KP42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.1 in
Width (in)5.5 in
Depth (in)3.4 in

Product details

SENTRON 3VA2116-7KP42-0AA0 — 160 A MCCB with ETU850, Active Production

Four poles, line protection version, fitted with the ETU850 electronic overcurrent release. The ETU850 provides adjustable long-time pickup and delay (tr min 0.5 s, tr max 20 s), short-time and instantaneous settings, plus ground-fault alarm or trip options — though this variant ships without the ground-fault monitoring module. Short-circuit breaking capacities span the voltage ladder: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.8 kA at 690 V. That 242 kA at 415 V gives substantial SCCR headroom for high-fault industrial services — useful when coordinating downstream with a transformer secondary or a large motor control center.

Panel Fit and Integration

Dimensions: 181 mm height, 140 mm width, 86 mm depth. The 140 mm width is standard for a 4-pole SENTRON 3VA2 frame — drops into the same panel cutout pattern as the 3VA2216-8JP42-0AA0 without rewiring, though verify the lug kit and accessory positions if swapping between variants. IP40 on the front face — suitable for enclosed panel mounting where the breaker is behind a door. Maximum power loss of 25.5 W at rated current; factor that into the enclosure thermal budget, especially in a multi-breaker lineup. Mechanical endurance rated at 20 000 operations — typical for a 160 A frame in distribution duty. Communication function is present on this variant, enabling integration with energy management or remote monitoring systems via the SENTRON communication modules.

Frequently asked questions

What is 3VA2116-7KP42-0AA0's listed depth?

The depth is 86 mm (3.4 in).

What is 3VA2116-7KP42-0AA0's listed width?

The width is 140 mm (5.5 in).

Will 3VA2116-7KP42-0AA0 drop into a panel specified around 3VA2216-8JP42-0AA0 without rewiring?

Yes — both share the same 140 mm width and 181 mm height, so the cutout and mounting pattern are identical. Verify the lug kit and any communication module positions, but the physical swap requires no panel rework.

MPN
3VA2116-7KP42-0AA0