Skip to main content
Siemens 3VA2116-8HN32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-8HN32-0AA0 SENTRON MCCB, 160 A, 3-Pole, ETU3

MPN3VA2116-8HN32-0AA0
Active

Siemens SENTRON 3VA2116-8HN32-0AA0, molded case circuit breaker, 160 A, 3-pole, ETU350 electronic trip unit, 330 kA at 415 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-8HN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2116-8HN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.19.7 W

Protection & Trip Unit

3VA2116-8HN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-8HN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-8HN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2116-8HN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-8HN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what the ratings mean

The Siemens 3VA2116-8HN32-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated 160 A continuous current, 3-pole, with an ETU350 electronic trip unit, designed for line protection in distribution panels. Its interrupting capacity hits 330 kA at 415 V — that's the fault current it can safely clear without welding contacts or rupturing the case, sized for high-available-fault installations like industrial substations or large motor control centers. The ETU350 electronic trip offers adjustable overload and short-circuit protection curves, giving the panel designer flexibility to coordinate with downstream breakers without swapping trip units. Rated insulation voltage is 800 V, so it's suitable for 690 V line-to-line systems common in European and IEC-based industrial plants.

Panel fit and integration

Dimensions are 105 mm wide, 181 mm high, 86 mm deep — fits standard Siemens SENTRON 3VA panel cutouts and busbar systems; the 86 mm depth leaves clearance behind the door for wiring gutters. Front face carries IP40 protection — suitable for indoor panel installation where no water spray is present; not rated for washdown environments. Power dissipation is 19.7 W maximum at rated load — factor that into enclosure thermal calculations to avoid derating adjacent devices.

MPN
3VA2116-8HN32-0AA0