Skip to main content
Siemens 3VA2116-8JQ46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-8JQ46-0AA0 SENTRON MCCB, 160 A, 4-Pole, 440

MPN3VA2116-8JQ46-0AA0
Active

Siemens SENTRON 3VA2116-8JQ46-0AA0, 4-pole molded case circuit breaker, 160 A rated continuous current, line protection version with ETU560 electronic trip unit, breaking capacity 440 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-8JQ46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2116-8JQ46-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V53 kA
Power loss, max.19.7 W
3VA2116-8JQ46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
3VA2116-8JQ46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-8JQ46-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-8JQ46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-8JQ46-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.1 in
Width (in)5.5 in
Depth (in)3.4 in

Product details

The Siemens SENTRON 3VA2116-8JQ46-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for 160 A continuous current at ambient temperatures from 40 °C up to 70 °C — no derating needed across that band. It is the line protection variant, meaning it protects feeders and distribution circuits, not motor branches. The ETU560 electronic trip unit gives you adjustable long-time delay (0.5 to 20 s) and N-conductor protection configurable from OFF to 100 % of phase current. Breaking capacity is the headline here: 440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 53 kA at 690 V. That puts it in the high-interrupting class — suitable for large transformer secondaries, main switchboards, or high-fault industrial distribution where a standard MCCB would weld shut.

What the ETU560 trip unit gives you

The ETU560 is an electronic, not thermal-magnetic, overcurrent release. That means you get adjustable long-time pickup and delay (Ir and tr), plus short-time and instantaneous settings — not just a fixed bimetal curve. The N-conductor protection can be switched off or set between 20 % and 100 % of the phase current, which matters for 4-wire distribution where neutral loading varies. Power loss is 19.7 W maximum at rated current — manageable for panel thermal budgeting. Mechanical endurance is 20,000 operations.

Mounts on a standard backplate or mounting plate. The 86 mm depth fits most enclosures with clearance for rear terminals and wiring.

Frequently asked questions

Does this MCCB have communication capability?

Yes, the communication function is integrated — this variant supports remote monitoring and trip indication through the SENTRON communication system.

MPN
3VA2116-8JQ46-0AA0