Skip to main content
Siemens 3VA2125-6HM36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2125-6HM36-0AA0 SENTRON MCCB, 25 A, 3-Pole, 242 k

MPN3VA2125-6HM36-0AA0
Active

Siemens SENTRON 3VA2125-6HM36-0AA0, molded case circuit breaker, 3-pole, 25 A continuous rated current, 242 kA breaking capacity at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2125-6HM36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2125-6HM36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.0.6 W
3VA2125-6HM36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2125-6HM36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2125-6HM36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2125-6HM36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2125-6HM36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Its adjustable thermal trip range spans 38 A to 300 A, giving the specifying engineer flexibility to match the breaker to the actual load without swapping the frame. Breaking capacity is the headline here: 242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. The steep drop to 3.7 kA at 690 V tells you this is a 240–500 V class device; at 690 V the interrupting capability is much lower, so verify the available fault current at that voltage before specifying. The unit does not include undervoltage release or communication functions; it's a straightforward line-protection MCCB with no frills.

Panel Fit and Thermal Performance

Operating temperature range is -25 °C to 70 °C, with no derating needed across the full 25 A rating from 40 °C through 70 °C — all temperature points show 25 A continuous, so the breaker holds its rating in warm cabinets.

Frequently asked questions

Where can I buy 3VA2125-6HM36-0AA0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is the breaking capacity of 3VA2125-6HM36-0AA0 at 240 V?

242 kA at 240 V AC, dropping to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V.

What are the physical dimensions of this MCCB?

105 mm wide, 181 mm high, 86 mm deep (4.13 in × 7.13 in × 3.39 in).

Does 3VA2125-6HM36-0AA0 include ground-fault monitoring?

Yes, it includes ground-fault monitoring via summation current formation on the L-conductor.

MPN
3VA2125-6HM36-0AA0