Skip to main content
Siemens 3VA2125-6HN32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2125-6HN32-0AA0 SENTRON Molded Case Circuit Break

MPN3VA2125-6HN32-0AA0
Active

Siemens SENTRON molded case circuit breaker, 3VA2125-6HN32-0AA0, 3-pole, 25 A, ETU350 electronic trip unit, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2125-6HN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2125-6HN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.0.6 W

Protection & Trip Unit

3VA2125-6HN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2125-6HN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2125-6HN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2125-6HN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2125-6HN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2125-6HN32-0AA0 is a SENTRON 3-pole molded case circuit breaker rated for 25 A continuous current, designed for line protection with an ETU350 electronic overcurrent release.

Breaking capacity and selectivity

Breaking capacity is voltage-dependent: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. That 242 kA at 240 V means this breaker can interrupt nearly a quarter-million amps under a bolted fault at that voltage — critical for high-fault-current panels fed close to a transformer. Rated insulation voltage is 800 V, so the breaker's internal clearance and creepage are sized for 690 V line-to-line systems with margin. The ETU350 electronic trip unit allows adjustable overload and short-circuit protection curves, giving the engineer selectivity coordination options a fixed-thermal breaker cannot match.

Deployment context

Front protection is IP40, meaning tools or fingers won't contact live parts from the front face, but the breaker is not sealed against dust ingress — install in a panel with an IP54 or higher enclosure when washdown or airborne particulates are present. Dimensions of 105 mm wide by 181 mm tall by 86 mm deep fit the standard SENTRON 3VA mounting footprint, so it drops into existing 3VA panel cutouts and bus-bar arrangements without re-drilling.

Frequently asked questions

Will 3VA2125-6HN32-0AA0 drop into a panel specified around 5SQ2370-2YA05 without rewiring?

The 3VA2125-6HN32-0AA0 uses the standard SENTRON 3VA mounting footprint (105 mm wide). The 5SQ2370-2YA05 is a different Siemens series with a different lug arrangement and bus-bar spacing — mechanical fit is not guaranteed without verifying the panel cutout and bus centers.

MPN
3VA2125-6HN32-0AA0