Siemens 3VA2125-6JP46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2125-6JP46-0AA0 SENTRON MCCB, 25 A, 4-Pole, ETU55

MPN3VA2125-6JP46-0AA0
Active

Siemens SENTRON 3VA2125-6JP46-0AA0, molded case circuit breaker, 4-pole, 25 A continuous, ETU550 electronic trip, interrupting 242 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2125-6JP46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2125-6JP46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.0.6 W

Protection & Trip Unit

3VA2125-6JP46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2125-6JP46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2125-6JP46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2125-6JP46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2125-6JP46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

MCCB with ETU550 — 25 A continuous, 4-pole, high interrupting capacity

The Siemens SENTRON 3VA2125-6JP46-0AA0 is a 4-pole molded case circuit breaker rated for 25 A continuous current, fitted with the ETU550 electronic trip unit. It is designed for line protection in distribution panels and switchboards where selective coordination and adjustable trip curves are required. The interrupting capacity reaches 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V — figures that govern its fault-clearing capability at each voltage level.

What the ratings mean for fit

The 25 A continuous rating is the breaker's nominal current under steady load — it is not a trip threshold but the current the breaker carries without exceeding its thermal limits. The ETU550 trip unit provides adjustable overload and short-circuit protection, so the breaker can be coordinated downstream of a larger feeder or upstream of branch circuits. The interrupting ratings (–) are the maximum fault currents the breaker can safely interrupt at each system voltage; at 690 V the 3.7 kA figure means this breaker is not suitable for high-fault 690 V applications — that voltage class typically requires a higher-rated frame. The 4-pole construction suits three-phase systems with a switched neutral or where all poles must open simultaneously.

Integration and mounting

The breaker measures 86 mm deep, 140 mm wide, and 181 mm high. It mounts in a standard panel or enclosure footprint for 4-pole MCCBs of this frame size. The front face carries IP40 protection.

Frequently asked questions

When sourcing 3VA2125-6JP46-0AA0, what's the closest functional second-source — 3VA2125-8KQ42-0AA0?

The 3VA2125-8KQ42-0AA0 is a peer in the same SENTRON 3VA2 frame family. The key difference is the trip unit: the 6JP46 uses an ETU550 electronic trip, while the 8KQ42 uses a different trip configuration. Verify the trip curve and communication requirements before substituting — the physical footprint and pole count are the same, but the protection settings may differ.

What is 3VA2125-6JP46-0AA0's listed depth (86 mm) on this component line?

The depth is 86 mm, which is 3.39 inches. This is the dimension from the mounting surface to the front of the breaker, not including any protruding handle or accessories.

Will 3VA2125-6JP46-0AA0 drop into a panel that was specified around 3VA2125-8KQ42-0AA0 without rewiring?

Both breakers share the same SENTRON 3VA2 frame dimensions and pole count, so the physical fit and bus-bar connections are identical. No rewiring of the panel is needed for the mechanical drop-in. However, the trip unit difference (ETU550 vs. the 8KQ42's unit) means the protection settings may require reconfiguration via the trip-unit interface.

MPN
3VA2125-6JP46-0AA0