Skip to main content
Siemens 3VA2125-7HM32-0BK0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2125-7HM32-0BK0 SENTRON MCCB, 25 A, 3-Pole, 330 k

MPN3VA2125-7HM32-0BK0

Siemens SENTRON 3VA2125-7HM32-0BK0, molded case circuit breaker, 3-pole, 25 A rated continuous current, ETU330 electronic trip unit, line protection version, breaking capacity 330 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2125-7HM32-0BK0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2125-7HM32-0BK0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.8 kA
Power loss, max.0.6 W
3VA2125-7HM32-0BK0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
3VA2125-7HM32-0BK0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2125-7HM32-0BK0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
3VA2125-7HM32-0BK0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2125-7HM32-0BK0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.1 in
Width (in)4.1 in

Product details

The Siemens SENTRON 3VA2125-7HM32-0BK0 is a 3-pole molded case circuit breaker (MCCB) rated for a continuous current Iu of 25 A across the full operating temperature range from 40 °C to 70 °C — no derating needed up to the 70 °C ceiling. That flat thermal curve simplifies panel sizing: the same 25 A frame handles a warm cabinet without a bump in conductor or enclosure rating. Breaking capacity runs 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.8 kA at 690 V. The ETU330 electronic trip unit provides adjustable long-time pickup (Ir) from 0.5 A to 25 A and adjustable long-time delay (tr) from 0.5 s to 17 s, letting you shape the trip curve to the load — motor start, feeder, or capacitor bank — without swapping the breaker.

Dimensions are 105 mm wide, 181 mm high, 86 mm deep — a standard MCCB footprint that fits a 3-pole SENTRON 3VA mounting base. Optional motor drive available as a product extension for remote trip or reclose — useful in unmanned substations or PLC-controlled distribution.

MPN
3VA2125-7HM32-0BK0