Skip to main content
Siemens 3VA2125-7JQ32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2125-7JQ32-0AA0 MCCB, 25 A, 3-Pole, 330 k

MPN3VA2125-7JQ32-0AA0
Active

Siemens SENTRON 3VA2125-7JQ32-0AA0, Molded case circuit breaker, 25 A, 3-pole, 330 kA interrupting at 240 V, line protection design with communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2125-7JQ32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2125-7JQ32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.0.6 W

Protection & Trip Unit

3VA2125-7JQ32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2125-7JQ32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2125-7JQ32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2125-7JQ32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2125-7JQ32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2125-7JQ32-0AA0 — 25 A MCCB, line protection, communication-ready

The Siemens SENTRON 3VA2125-7JQ32-0AA0 is a 3-pole molded case circuit breaker rated 25 A continuous, designed for line protection in distribution panels. Its interrupting capacity reaches 330 kA at 240 V, 242 kA at 415 V, and 187 kA at 500 V, dropping to 3.7 kA at 690 V — which means it handles high-fault utility feeds at typical low-voltage levels but is not intended for 690 V distribution. The 25 A rating holds flat from 40 °C through 70 °C (–), so no derating is needed in warm enclosures. A communication function allows integration with building management or power monitoring systems.

Mounting & panel fit — 105 mm wide, 86 mm deep, 181 mm tall

The 3VA2125-7JQ32-0AA0 measures 105 mm wide, 86 mm deep, and 181 mm tall. It mounts on a DIN rail or panel-mount plate inside a standard distribution enclosure. The 3-pole footprint matches typical SENTRON 3VA series cutouts — no surprises for panel builders already working with that family.

Electrical ratings — what the numbers mean for your BOM

Rated continuous current is 25 A with a full-scale setting of 25 A — the breaker is fixed at that value, not adjustable. The minimum operating current is 38 A and maximum 300 A. Rated insulation voltage is 800 V. Power loss is 0.6 W maximum.

Frequently asked questions

What are the key dimensions of 3VA2125-7JQ32-0AA0?

Width 105 mm, depth 86 mm, height 181 mm. Fits standard SENTRON 3VA panel cutouts.

MPN
3VA2125-7JQ32-0AA0