The Siemens SENTRON 3VA2140-0KP42-0AA0 is a 4-pole molded case circuit breaker (MCCB) carrying a 40 A continuous current rating and an ETU850 electronic trip unit. The ETU850 is a microprocessor-based release that gives you adjustable long-time, short-time, instantaneous, and ground-fault protection curves — meaning you can coordinate this breaker downstream of a larger feeder without nuisance tripping, and set the N-conductor protection anywhere from OFF to 40%–160% of the phase rating. The headline breaking capacity is 440 kA at 415 V AC and 187 kA at 690 V AC. At 690 V the 187 kA rating still covers most industrial distribution bus faults. The adjustable trip range spans 60 A minimum to 480 A maximum, so while the breaker is rated for 40 A continuous (the frame size), the electronic trip can be dialed up to protect a circuit drawing up to 480 A — typical for a feeder feeding multiple downstream sub-panels or a large motor control center. The 40 A continuous rating holds flat across the full ambient temperature range from -25 °C to 70 °C, with no derating needed. Panel footprint: 181 mm high, 140 mm wide, 86 mm deep. IP40 front protection is standard for switchboard mounting.
Siemens 3VA2140-0KP42-0AA0 SENTRON MCCB, 40 A, 4-Pole, ETU85
MPN3VA2140-0KP42-0AA0
Active
Siemens SENTRON 3VA series, molded case circuit breaker, 3VA2140-0KP42-0AA0, 40 A continuous, 4-pole, ETU850 electronic trip unit, 440 kA at 415 V.
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Parameter | Value |
|---|---|
| Number of poles | 4 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 40 A |
| Current at 45 °C | 40 A |
| Current at 50 °C | 40 A |
| Current at 55 °C | 40 A |
| Current at 60 °C | 40 A |
| Current at 65 °C | 40 A |
| Current at 70 °C | 40 A |
| Switching capacity class | E |
| Breaking capacity at 415 V | 440 kA |
| Breaking capacity at 690 V | 187 kA |
| Power loss, max. | 1.2 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | ETU850 |
| Overcurrent protection function | LSI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
| Parameter | Value |
|---|---|
| Main circuit connection type | on both sides nut keeper kit |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | No |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | Yes |
| Measurement function | Yes |
| Motor drive option | Yes |
| Auxiliary CO contacts | 0 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 25 000 |
| Height | 181 mm |
| Width | 140 mm |
| Depth | 86 mm |
| Height (in) | 7.13 in |
| Width (in) | 5.51 in |
| Depth (in) | 3.39 in |
Product details
Frequently asked questions
What does the ETU850 trip unit allow me to adjust?
The ETU850 is an electronic trip unit with adjustable long-time, short-time, instantaneous, and ground-fault protection. The N-conductor protection can be set to OFF or from 40% to 160% of the phase rating.
MPN
3VA2140-0KP42-0AA0