Siemens 3VA2140-5KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5KQ42-0AA0 SENTRON MCCB, 40 A, 4-Pole, 121 k

MPN3VA2140-5KQ42-0AA0
Active

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2140-5KQ42-0AA0, 40 A, 4-pole, ETU860 electronic trip unit, line protection, 121 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2140-5KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2140-5KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W
3VA2140-5KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
3VA2140-5KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-5KQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-5KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-5KQ42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What this 40 A SENTRON MCCB delivers

The Siemens 3VA2140-5KQ42-0AA0 is a 4-pole molded case circuit breaker from the SENTRON 3VA2 series, rated at 40 A continuous current (Iu) across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Breaking capacity hits 121 kA at 415 V and 440 V, and 187 kA at 240 V, so it handles high-fault utility feeds and transformer secondaries without cascading upstream. This is a line-protection device — it guards distribution feeders and large branch circuits, not motor starters. The communication function lets it talk to a higher-level monitoring system for power-quality data and trip-event logging, which is useful if you're tracking arc-flash incident energy or doing selective coordination studies.

The optional motor drive lets you remote-trip or remote-reset the breaker for unattended restart schemes.

Frequently asked questions

Where can I buy the 3VA2140-5KQ42-0AA0 and get a price?

We source and quote this part to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What are the key ratings for the 3VA2140-5KQ42-0AA0?

It is a 40 A continuous rated, 4-pole MCCB with an ETU860 electronic trip unit. Breaking capacity is 121 kA at 415 V and 440 V, 187 kA at 240 V, 75.6 kA at 500 V, and 3.7 kA at 690 V (–). Insulation voltage is 800 V.

What is the depth of the 3VA2140-5KQ42-0AA0?

The depth is 86 mm.

What is the width of the 3VA2140-5KQ42-0AA0?

The width is 140 mm.

Will the 3VA2140-5KQ42-0AA0 drop into a panel specified for the 3VA2140-8JQ42-0AA0?

Both are 4-pole 3VA2 frame breakers with the same mounting footprint — same height, width, and depth class. The difference is the trip unit: the -5KQ42-0AA0 carries the ETU860 electronic release with ground-fault summation monitoring, while the -8JQ42-0AA0 uses a different release variant. Panel cutouts and bus-bar spacing are identical; the swap is mechanical but check the trip-unit coordination study before substituting.

MPN