Skip to main content
Siemens 3VA2140-0MN36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-0MN36-0AA0 SENTRON MCCB, 40 A, 3-Pole, ETU35

MPN3VA2140-0MN36-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2140-0MN36-0AA0, 40 A, 3-pole, ETU350M electronic trip unit, adjustable trip class 10A/10E/20E, 440 kA at 415 V, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-0MN36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2140-0MN36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.1.2 W
3VA2140-0MN36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2140-0MN36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-0MN36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-0MN36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-0MN36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

It's a current-production part — still in active manufacture, so no scavenging needed for new builds or spares. Three poles, electronic ETU350M trip unit with adjustable trip classes 10A, 10E, and 20E — that covers most standard motor start profiles from quick-start pumps to higher-inertia conveyors.

Breaking capacity — the real number that matters for selectivity

The 440 kA at 415 V is the headline, but the 187 kA at 690 V is what you care about if you're feeding a 690 V drive or transformer. That's a serious interrupting rating — it'll hold fault current through a high-capacity transformer secondary without cascading upstream.

Footprint is 105 mm wide by 181 mm tall by 86 mm deep — standard 3-pole MCCB envelope for the SENTRON 3VA2 family. If you need those add-ons, you're looking at a different variant in the 3VA2 range.

Lifecycle status is current — no end-of-life notice, no last-time-buy clock ticking. That means you can spec it into a BOM without worrying about a forced redesign next year.

Frequently asked questions

What is the breaking capacity of 3VA2140-0MN36-0AA0?

440 kA at 415 V and 187 kA at 690 V, making it suitable for high-fault-current installations like transformer secondaries.

What trip classes does the ETU350M offer?

Adjustable trip classes 10A, 10E, and 20E — covers quick-start pumps through higher-inertia conveyor loads.

Where can I buy 3VA2140-0MN36-0AA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN