Siemens 3VA2140-5MN36-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5MN36-0AB0 SENTRON MCCB, 40 A, 187 kA at 240

MPN3VA2140-5MN36-0AB0

Siemens SENTRON 3VA2140-5MN36-0AB0, molded case circuit breaker, 3-pole, 40 A, motor protection design, 187 kA at 240 V, 121 kA at 415 V, 105 x 181 x 86 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-5MN36-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21405MN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA2140-5MN36-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-5MN36-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2140-5MN36-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-5MN36-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2140-5MN36-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-5MN36-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2140-5MN36-0AB0 — 40 A MCCB for Motor Protection

The Siemens 3VA2140-5MN36-0AB0 is a 3-pole molded case circuit breaker from the SENTRON family, designed specifically for motor protection. It carries a continuous current rating of 40 A across the full ambient temperature range from 40 °C to 70 °C, meaning no derating is needed in a warm panel — a practical advantage when the breaker sits near other heat-generating devices. The 187 kA interrupting capacity at 240 V and 121 kA at 415 V give it the headroom to clear high-fault conditions without cascading upstream, which simplifies coordination studies in a distribution board.

Motor Protection and Phase Failure Detection

This MCCB is built for motor protection duty, with integrated phase failure detection. That means it will trip if one phase drops out — a common failure mode that can single-phase a motor and burn it out if the overload relay doesn't catch it fast enough. The design eliminates the need for a separate phase-failure relay in the motor branch circuit, saving a DIN-rail slot and a wiring step. The basic switch is order code 3VA21405MN360AA0, and the auxiliary switch configuration is two HP-style aux switches, which can be wired for remote status indication or interlocking.

Breaking Capacity and Selectivity

The interrupting ratings are given at five voltage levels: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V (–). The sharp drop at 690 V is typical for a 40 A frame — the arc energy at that voltage exceeds what the compact arc chutes can extinguish at high current. For a 400 V distribution system, the 121 kA rating covers most industrial transformer sizes up to about 2.5 MVA. The minimum trip time is 4 s, maximum 17 s, which is a thermal-magnetic or electronic trip curve suited for motor starting inrush without nuisance tripping.

Physical Fit and Panel Integration

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep (–). That is a standard SENTRON 3VA2 frame size — it mounts on a DIN rail or can be screw-mounted to a backplate. The 86 mm depth means it will clear a standard 200 mm deep enclosure with room for wiring gutters. No undervoltage release, no voltage trip, no communication module, and no ground-fault monitoring are built in; if those functions are needed, they must be added via external accessories or a different variant.

Frequently asked questions

What is the breaking capacity of 3VA2140-5MN36-0AB0 at 415 V?

The interrupting rating is 121 kA at 415 V. At 240 V it is 187 kA, at 440 V it is 121 kA, at 500 V it is 75.6 kA, and at 690 V it is 3.7 kA.

Where can I buy 3VA2140-5MN36-0AB0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Does 3VA2140-5MN36-0AB0 have phase failure protection?

Yes, phase failure detection is included. The breaker will trip on loss of a phase, protecting the motor from single-phasing.