Skip to main content
Siemens 3VA2140-0HN36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-0HN36-0AA0 SENTRON MCCB, 40 A, 3-Pole, ETU35

MPN3VA2140-0HN36-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2140-0HN36-0AA0, 40 A, 3-pole, ETU350 electronic trip unit, 440 kA breaking capacity at 415 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-0HN36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2140-0HN36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.1.2 W
3VA2140-0HN36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2140-0HN36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-0HN36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-0HN36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-0HN36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The ETU350 electronic trip unit gives adjustable long-time, short-time, and instantaneous pickup, so you can tune coordination with downstream breakers. Three poles cover three-phase circuits.

The 3VA2140-0HN36-0AA0 measures 105 mm wide, 181 mm high, and 86 mm deep — a standard SENTRON 3VA2 frame footprint. It mounts via screw terminals or plug-in base (depending on the accessory selected) into a switchboard or enclosure. The IP40 front protection means the breaker face is protected against tools and solid objects over 1 mm, but the enclosure itself must provide the overall panel IP rating.

Frequently asked questions

Where can I buy 3VA2140-0HN36-0AA0 and get a price?

This part is sourced through independent distribution channels and quoted to order against an RFQ. Submit a request for current availability and pricing.

What is the breaking capacity of 3VA2140-0HN36-0AA0?

440 kA at 415 V AC and 187 kA at 690 V AC.

What trip unit does this MCCB use?

The ETU350 electronic trip unit provides adjustable long-time, short-time, and instantaneous protection.

MPN
3VA2140-0HN36-0AA0