Siemens 3VA2140-5HL32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5HL32-0AB0 SENTRON MCCB, 40 A, 3-Pole, 187 k

MPN3VA2140-5HL32-0AB0

Siemens SENTRON 3VA2140-5HL32-0AB0, molded case circuit breaker, 3-pole, 40 A, ETU320 electronic trip unit, 187 kA breaking capacity at 240 VAC, 86 mm depth, 105 mm width.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-5HL32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21405HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA2140-5HL32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-5HL32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2140-5HL32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-5HL32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2140-5HL32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-5HL32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what it does

The Siemens SENTRON 3VA2140-5HL32-0AB0 is a 3-pole molded case circuit breaker (MCCB) rated for 40 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to that ceiling. It carries a 187 kA interrupting capacity at 240 VAC and 121 kA at 415/440 VAC, which puts it in the high-fault category for industrial distribution panels and motor control centers where available fault current is significant. The ETU320 electronic trip unit provides adjustable overload and short-circuit protection curves, a step up from fixed thermal-magnetic releases for coordination selectivity.

Breaking capacity — what the numbers mean

The 187 kA at 240 VAC and 121 kA at 415 VAC are the ultimate short-circuit breaking capacities (Icu) per IEC 60947-2. At 500 VAC it still clears 75.6 kA, and at 690 VAC the rating drops to 3.7 kA — a steep fall that reflects the arc-extinction challenge at higher voltages. For a 480 VAC panel (common in North America), the 75.6 kA at 500 VAC is the closest reference; for 400 VAC systems (Europe/Asia), the 121 kA at 415 VAC applies. The rated insulation voltage is 800 V, so the breaker is electrically rated for 690 VAC systems but with the interrupting capability at that voltage confirmed at 3.7 kA.

Trip unit and auxiliary configuration

The ETU320 electronic trip unit is the overcurrent release on this variant. It supports LSI protection (long-time, short-time, instantaneous) with adjustable pickups and time delays, which is what you need for selective coordination downstream of a transformer or upstream of feeder breakers. The breaker ships with two HP auxiliary switches built in — no separate add-on module required for status feedback to a PLC or SCADA. The basic switch order code is 3VA21405HL320AA0, which is the internal switching mechanism; the full breaker includes it. There is no undervoltage release, no ground-fault monitoring, and no communication function on this order code — it is a straight power distribution breaker.

Physical fit and panel integration

Dimensions are 105 mm wide, 181 mm tall, and 86 mm deep. The 105 mm width is standard for a 3-pole SENTRON 3VA2 frame — it fits the same mounting footprint as other 3VA2 breakers in the same frame size. Front IP40 protection means it is suitable for enclosed panel mounting where tools are required to access live parts; no washdown rating. The breaker is designed for screw-mounting to a backplate or mounting plate, not DIN rail. Operating temperature range is -25 °C to 70 °C, storage from -40 °C to 80 °C.

Frequently asked questions

Where can I buy 3VA2140-5HL32-0AB0 and get a price?

This part is sourced through independent distribution and quoted to order against an RFQ. Submit a request for current availability and pricing — confirmed at quote time.

What is the breaking capacity of 3VA2140-5HL32-0AB0 at 240 V?

The ultimate short-circuit breaking capacity (Icu) at 240 VAC is 187 kA. At 415 VAC it is 121 kA, at 500 VAC it is 75.6 kA, and at 690 VAC it is 3.7 kA.

What trip unit does 3VA2140-5HL32-0AB0 use?

It uses the ETU320 electronic trip unit with LSI protection (long-time, short-time, instantaneous), adjustable pickups and time delays.