Siemens 3VA2140-5HM32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5HM32-0AA0 SENTRON MCCB, 40 A, 187 kA at 240

MPN3VA2140-5HM32-0AA0
Active

Siemens SENTRON 3VA2140-5HM32-0AA0, molded case circuit breaker (MCCB), 3-pole, 40 A rated continuous current, 187 kA interrupting rating at 240 V AC, ETU330 electronic trip unit, line protection version.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-5HM32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2140-5HM32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V76 kA
Breaking capacity at 690 V3.8 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-5HM32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330

Construction & Connection

3VA2140-5HM32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-5HM32-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2140-5HM32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-5HM32-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.1 in
Width (in)4.1 in
Depth (in)3.4 in

Product details

What this 40 A MCCB delivers

The Siemens SENTRON 3VA2140-5HM32-0AA0 is a 3-pole molded case circuit breaker rated for 40 A continuous current (Iu) across the full operating range from -40 °C to 70 °C — no derating needed up to 70 °C ambient. Its interrupting capacity hits 187 kA at 240 V AC, dropping to 121 kA at 415/440 V, 76 kA at 500 V, and 3.8 kA at 690 V. That 187 kA figure at 240 V gives you serious fault-current headroom for high-capacity transformer-fed panels or large motor control centers where available fault current is substantial.

Trip unit and protection profile

Fitted with the ETU330 electronic overcurrent release, this MCCB offers adjustable long-time delay (tr) from 0.5 to 17 seconds. The line protection version means it's configured for cable and busbar protection rather than motor or generator duty. No communication function onboard — this is a standalone thermal-magnetic replacement with electronic trip precision.

Panel fit and mounting

Dimensions are 105 mm wide, 181 mm tall, and 86 mm deep — a standard SENTRON 3VA form factor that fits existing 3VA panel cutouts and busbar systems. Front IP40 protection keeps dust out of the enclosure face. An optional motor drive is available for remote switching. Mounts via screw fixing to the mounting plate; no DIN-rail clip on this frame size.

Lifecycle and sourcing posture

Marked as current production — no end-of-life notice or last-time-buy window on record. This is a standard catalog item in the SENTRON 3VA line, widely specified for distribution panels and switchboards. Sourced to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Frequently asked questions

What trip unit does this MCCB use?

The ETU330 electronic overcurrent release with adjustable long-time delay from 0.5 to 17 seconds.

MPN
3VA2140-5HM32-0AA0