Siemens 3VA2140-5HN42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5HN42-0AA0 SENTRON 4P MCCB, 40 A, ETU350, 18

MPN3VA2140-5HN42-0AA0
Active

Siemens SENTRON 3VA series, molded case circuit breaker (MCCB), 4-pole, 40 A continuous rating, ETU350 electronic trip unit, 187 kA breaking capacity at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-5HN42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2140-5HN42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-5HN42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2140-5HN42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-5HN42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2140-5HN42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-5HN42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What this 40 A MCCB delivers — and what the ratings actually mean for your panel

The Siemens SENTRON 3VA2140-5HN42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for 40 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel build in warm enclosures or near heat sources. Its ETU350 electronic trip unit provides adjustable overload and short-circuit protection curves, with N-conductor protection configurable to OFF or 100 % — a feature that matters when you need to protect a fully rated neutral in a 4-wire system. Breaking capacity hits 187 kA at 240 V AC and 121 kA at 415/440 V, tapering to 75.6 kA at 500 V and 3.7 kA at 690 V — the 690 V figure is low enough that you need to verify coordination upstream if the service voltage sits near that ceiling. Rated insulation voltage is 800 V, and the front face carries IP40 protection — fine for a clean indoor panel, but not for washdown zones.

Panel fit and integration notes

Dimensions are 181 mm height, 140 mm width, 86 mm depth — standard SENTRON 3VA footprint for a 4-pole frame at this rating. No undervoltage release, no voltage trigger, no communication module, and no ground-fault monitoring on this variant — it is a straight line-protection breaker with the ETU350 trip unit and a mechanical trip indicator absent. Power loss is rated at 1.6 W maximum — negligible for thermal budgeting inside a crowded panel.

Frequently asked questions

Does this breaker include ground-fault monitoring or a communication module?

No — this variant has no ground-fault monitoring, no communication function, and no undervoltage release. It is a line-protection MCCB with the ETU350 trip unit.

MPN
3VA2140-5HN42-0AA0