Siemens 3VA2140-5JQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5JQ42-0AA0 SENTRON MCCB, 40 A, 4-Pole, 187 k

MPN3VA2140-5JQ42-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 40 A continuous rated current, 4-pole, adjustable thermal-magnetic trip 60–480 A, breaking capacity 187 kA at 240 VAC, 86 mm depth, 140 mm width, 181 mm height.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-5JQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2140-5JQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-5JQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes

Construction & Connection

3VA2140-5JQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-5JQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2140-5JQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-5JQ42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What this MCCB delivers

The Siemens 3VA2140-5JQ42-0AA0 is a 4-pole SENTRON molded case circuit breaker (MCCB) rated for 40 A continuous current, with an adjustable thermal-magnetic trip unit spanning 60 A minimum to 480 A maximum — meaning you set the actual protection point within that window to match the downstream load. Breaking capacity is 187 kA at 240 VAC, dropping to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the 240 V figure tells you this breaker handles high available fault current at lower voltages typical of North American distribution panels. Rated insulation voltage is 800 V, and the breaker carries a communication function for integration into higher-level monitoring or control schemes — not just a standalone overcurrent device. Ground-fault monitoring uses summation current formation on L+N conductors, so it detects leakage without a separate GFCI module.

Sizing and selectivity

The 40 A continuous rating holds flat from 40 °C through 70 °C ambient — no derating needed across that temperature band, which simplifies panel layout in warm enclosures. Maximum power loss is 1.6 W, low enough that adjacent devices see minimal heat rise in a crowded DIN-rail or panel-mount arrangement. The adjustable trip range (60–480 A) lets you coordinate with upstream and downstream devices for selective coordination — set the magnetic pickup above the inrush of downstream motor starters or downstream MCCBs.

Physical fit and environment

Dimensions are 86 mm deep, 140 mm wide, 181 mm high — the width is the critical panel cutout dimension; verify against existing busbar or mounting base spacing. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C — the storage limit governs handling and warehousing, not running conditions. Designed for line protection (not motor or generator protection), so the trip curve and time-delay characteristics are optimized for feeder and branch-circuit duty.

Frequently asked questions

Will 3VA2140-5JQ42-0AA0 drop into a panel specified around 5SQ2670-2YA63 without rewiring?

Not without checking the mounting footprint and busbar spacing — the 3VA2140-5JQ42-0AA0 is 86 mm deep, 140 mm wide, 181 mm tall; compare those against the 5SQ2670-2YA63's dimensions before assuming a drop-in fit.

MPN
3VA2140-5JQ42-0AA0