Siemens 3VA2140-5MN32-0JL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5MN32-0JL0 SENTRON MCCB, 40 A, 3-Pole, 187 k

MPN3VA2140-5MN32-0JL0

Siemens SENTRON 3VA2140-5MN32-0JL0, molded case circuit breaker, motor protection design, 3-pole, 40 A, 187 kA at 240 V, with shunt trip and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2140-5MN32-0JL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21405MN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2140-5MN32-0JL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W
3VA2140-5MN32-0JL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2140-5MN32-0JL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-5MN32-0JL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2140-5MN32-0JL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-5MN32-0JL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Rated 187 kA at 240 V and 121 kA at 415/440 V, it handles high available fault currents common in industrial distribution panels without cascading upstream. At 500 V the breaking capacity is 75.6 kA; at 690 V it drops to 3.7 kA — a normal curve for a 40 A frame, but worth noting if the line side runs at 690 V.

Integration & Fit

The base switch is order code 3VA21405MN320AA0, meaning the breaker core is a fixed unit — not a plug-in or draw-out variant. Field-installable accessories are limited to the provided shunt trip and auxiliary switch block; no communication module or ground-fault module is fitted.

Ratings & Protection

Maximum power loss is 1.6 W at rated current, which keeps enclosure heating minimal.

Frequently asked questions

Does 3VA2140-5MN32-0JL0 include phase failure detection?

Yes, it includes phase failure detection.

What auxiliary switches and releases are fitted on 3VA2140-5MN32-0JL0?

Two auxiliary switches, one trip alarm switch, one electrical alarm switch (HQ), and a shunt trip release (STL).

MPN