Siemens 3VA2140-5MN32-0KL0 SENTRON MCCB, 40 A, 121 kA at 415

MPN3VA2140-5MN32-0KL0

Siemens SENTRON 3VA2140-5MN32-0KL0, molded case circuit breaker, 3-pole, 40 A, 121 kA at 415 V, motor protection design, with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-5MN32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21405MN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2140-5MN32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-5MN32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2140-5MN32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-5MN32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2140-5MN32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-5MN32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB for motor protection — 40 A, 121 kA at 415 V

The Siemens SENTRON 3VA2140-5MN32-0KL0 is a 3-pole molded case circuit breaker (MCCB) rated 40 A continuously from 40 °C up through 70 °C ambient — no derating needed across that span, which simplifies panel design in warm enclosures. Its interrupting capacity hits 121 kA at 415 V, enough for high-fault utility feeds or transformer secondaries without cascading upstream. The motor-protection design includes phase failure detection, so it catches a lost phase before the winding overheats.

Built-in accessories — shunt trip and auxiliary switches

This breaker ships with a shunt trip release (STL) for remote tripping and a complement of auxiliary switches: two auxiliary switches plus one trip alarm switch plus one electrical alarm switch HQ. That covers remote status indication and emergency-off integration without adding external relay logic. The trip indicator and voltage trigger are present, so a downstream PLC or SCADA gets a clear signal on the event.

Dimensions and panel fit

At 86 mm deep, 105 mm wide, and 181 mm tall, the 3VA2140-5MN32-0KL0 fits the standard SENTRON 3VA footprint. Panel cutout and bus-bar spacing match the 3VA family — no re-drilling if you are swapping from another 3VA frame. The 3-pole block occupies a single mounting position in a distribution board or motor control center.

Frequently asked questions

What is the breaking capacity of 3VA2140-5MN32-0KL0 at 415 V?

The interrupting rating is 121 kA at 415 V. At 240 V it reaches 187 kA; at 500 V it drops to 75.6 kA; at 690 V it is 3.7 kA.

Where can I buy 3VA2140-5MN32-0KL0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does 3VA2140-5MN32-0KL0 include a shunt trip?

Yes, the design of the auxiliary release includes a shunt trip (STL). It also ships with two auxiliary switches, one trip alarm switch, and one electrical alarm switch HQ.

MPN