Siemens 3VA2140-6HM46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-6HM46-0AA0 SENTRON MCCB, 4P, 40A, 60-480A Ad

MPN3VA2140-6HM46-0AA0
Active

Siemens SENTRON 3VA2 molded case circuit breaker, 4-pole, 40 A rated continuous current, adjustable thermal overload trip 60–480 A, 242 kA breaking capacity at 240 V AC, line protection design with integral ground-fault monitoring.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-6HM46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2140-6HM46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-6HM46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes

Construction & Connection

3VA2140-6HM46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-6HM46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2140-6HM46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-6HM46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

SENTRON 3VA2 MCCB — line protection with ground-fault monitoring

The Siemens 3VA2140-6HM46-0AA0 is a SENTRON 3VA2-series molded case circuit breaker (MCCB) designed for line protection in distribution panels. It carries a rated continuous current of 40 A with an adjustable thermal overload trip range from 60 A minimum to 480 A maximum, so the same breaker body can be tuned to protect a feeder sized anywhere within that window — useful when stocking a single frame for multiple branch ratings. Breaking capacity is rated per the voltage it sees: 242 kA at 240 V AC, 187 kA at both 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. The steep drop at 690 V means this frame is not the right choice for a 690 V feeder with high prospective fault current — verify the available fault current at the installation point against the 3.7 kA ceiling. The 4-pole configuration with integral summation ground-fault monitoring (L + N conductor) covers applications where residual current detection is required without a separate RCD module — common in North American and European distribution where ground-fault protection is specified at the breaker rather than downstream.

Thermal performance — no derating across the operating range

Rated current holds at 40 A continuously from 40 °C through 70 °C ambient, per the spec table. No derating curve to calculate for panel internal temperatures up to 70 °C — the breaker is rated flat across that band. Operating ambient minimum is -25 °C; storage range is -40 °C to 80 °C. Maximum power loss is 1.6 W at rated load — negligible for panel thermal budgeting, but worth noting if the breaker is ganged in a multi-unit enclosure with limited convection.

Panel fit and dimensions

Footprint is 140 mm wide × 181 mm high × 86 mm deep (5.51 × 7.13 × 3.39 in). The 4-pole width at 140 mm is standard for a 4-pole MCCB frame in this class; verify the mounting base cutout and bus-bar spacing against the existing panel layout before ordering.

Frequently asked questions

Does this breaker include ground-fault protection?

Yes — it has integral summation ground-fault monitoring on the L + N conductors, so it can detect residual current without a separate RCD module.

What is the adjustable trip range on 3VA2140-6HM46-0AA0?

The thermal overload trip is adjustable from 60 A minimum to 480 A maximum, allowing one frame to cover multiple feeder ratings.

MPN
3VA2140-6HM46-0AA0