Siemens 3VA2140-6JQ32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-6JQ32-0DH0 SENTRON MCCB, 40 A, 3-Pole, 242 k

MPN3VA2140-6JQ32-0DH0

Siemens SENTRON 3VA series, molded case circuit breaker (MCCB), 3VA2140-6JQ32-0DH0, 40 A rated, 3-pole, breaking capacity 242 kA at 240 V, line protection design, with undervoltage release and communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2140-6JQ32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21406JQ320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2140-6JQ32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4.1 W
3VA2140-6JQ32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2140-6JQ32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-6JQ32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2140-6JQ32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-6JQ32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2140-6JQ32-0DH0 — 40 A MCCB with flat thermal derating to 70 °C

The Siemens SENTRON 3VA2140-6JQ32-0DH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a full-scale value of 40 A and a minimum trip setting of 1.5 A. Breaking capacity reaches 242 kA at 240 V, stepping down to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. That gives you headroom for high-fault installations without oversizing the frame.

The UVR ensures the breaker trips on loss of control voltage — standard for emergency-stop chains or safety isolation where you need the load guaranteed off when the control supply drops. Communication function is built in, so it can report status to a higher-level system without an add-on module. A trip indicator is present for visual confirmation at the panel face.

Maximum power loss is 4.1 W, which keeps internal enclosure temperature rise manageable even in a densely packed cabinet.

Frequently asked questions

What is the breaking capacity of this MCCB at different voltages?

Breaking capacity is 242 kA at 240 V, 187 kA at both 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V.

Does the 3VA2140-6JQ32-0DH0 include an undervoltage release?

Yes, it includes an integrated undervoltage release (UVR) as standard, plus 2 auxiliary switches and 1 trip alarm switch.

Where can I buy 3VA2140-6JQ32-0DH0 and what is the lead time?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm delivery commitment.

MPN
3VA2140-6JQ32-0DH0