Skip to main content
Siemens 3VA2140-6JQ36-0AA0 — Molded Case Circuit Breakers (MCCB)

3VA2140-6JQ36-0AA0 SENTRON MCCB, 40 A, 3-pole, 242 kA at 240

MPN3VA2140-6JQ36-0AA0
Active

SENTRON 3VA2140-6JQ36-0AA0, molded case circuit breaker, 40 A, 3-pole, line protection, 242 kA at 240 V, 105 x 181 x 86 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-6JQ36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2140-6JQ36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-6JQ36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2140-6JQ36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-6JQ36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2140-6JQ36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-6JQ36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

SENTRON 3VA2140-6JQ36-0AA0 — 40 A MCCB, 242 kA at 240 V, line protection

This 3-pole molded case circuit breaker from the SENTRON family is rated for 40 A continuous current and delivers a 242 kA breaking capacity at 240 V, dropping to 187 kA at 415 V and 121 kA at 500 V — at 690 V the interrupt rating is 3.7 kA. That wide spread tells you the part is sized for high-fault low-voltage distribution panels, not for 690 V motor circuits. It's a line-protection design, so it guards the feeder, not a specific load. The 40 A rating holds flat from 40 °C through 70 °C ambient — no derating needed in a warm enclosure up to that point. The part carries a communication function and ground-fault monitoring via summation current formation on the L-conductor. Rated insulation voltage is 800 V. Dimensions are 105 mm wide, 181 mm high, 86 mm deep — standard MCCB footprint for a 3-pole frame at this ampacity.

Panel fit & integration

Mounts into a standard DIN-rail or bolted bus-bar panel — 105 mm width fits a typical 3-pole MCCB slot. The 86 mm depth leaves room for rear bus connections and cable bending radius inside a 200 mm deep enclosure. No special cutout or adapter plate required for a SENTRON 3VA frame.

Frequently asked questions

How do I get current pricing and availability for 3VA2140-6JQ36-0AA0?

Submit an RFQ against this order code — pricing and availability are confirmed at quote time through independent distribution channels.

What are the key ratings of 3VA2140-6JQ36-0AA0?

It's a 3-pole, 40 A continuous MCCB with 242 kA breaking capacity at 240 V, 187 kA at 415 V, and 3.7 kA at 690 V. Rated insulation voltage is 800 V.

What is the width of 3VA2140-6JQ36-0AA0?

The width is 105 mm.

What is the depth of 3VA2140-6JQ36-0AA0?

The depth is 86 mm.

MPN
3VA2140-6JQ36-0AA0