Skip to main content
Siemens 3VA2140-7HL46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-7HL46-0AA0 SENTRON MCCB, 4P, 40A, ETU320, 33

MPN3VA2140-7HL46-0AA0
Active

Siemens SENTRON 3VA2140-7HL46-0AA0, molded case circuit breaker, 4-pole, 40 A continuous, ETU320 electronic trip unit, breaking capacity 330 kA at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-7HL46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2140-7HL46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-7HL46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2140-7HL46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-7HL46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2140-7HL46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-7HL46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Siemens 3VA2140-7HL46-0AA0 — 4-pole MCCB with ETU320 trip unit

The Siemens 3VA2140-7HL46-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection in industrial power distribution. It is a 4-pole unit rated for 40 A continuous current. The electronic trip unit ETU320 provides adjustable overload and short-circuit protection, covering a current setting range from 60 A to 480 A. Breaking capacity is specified across multiple voltage levels: 330 kA at 240 V AC, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. These are the maximum short-circuit currents the breaker can safely interrupt at the respective voltages — critical for sizing upstream protection and ensuring coordination in high-fault panels. The breaker measures 86 mm deep, 140 mm wide, and 181 mm high. It mounts on a DIN rail or directly in a panel enclosure; the 4-pole width (140 mm) matches the standard SENTRON 4-pole footprint, so it slots into existing MCCB layouts without re-drilling gland plates.

Thermal performance and installation notes

Continuous current rating holds at 40 A across the full ambient temperature range from 40 °C to 70 °C (–). That means no derating is needed in warm enclosures — the breaker delivers its full 40 A even at 70 °C ambient. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. Rated insulation voltage is 800 V. Front protection class is IP40 — suitable for general indoor panel use, not washdown environments. Power loss at rated current is 1.6 W maximum.

Frequently asked questions

Where can I buy 3VA2140-7HL46-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2140-7HL46-0AA0 at 240 V?

The breaking capacity is 330 kA at 240 V AC.

What trip unit does 3VA2140-7HL46-0AA0 use?

It uses the ETU320 electronic overcurrent release.

MPN
3VA2140-7HL46-0AA0