Siemens 3VA2140-7KQ32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-7KQ32-0AA0 SENTRON MCCB, 40 A, 330 kA at 240

MPN3VA2140-7KQ32-0AA0
Active

Siemens SENTRON 3VA2140-7KQ32-0AA0, 3-pole molded case circuit breaker, 40 A rated continuous current, 330 kA interrupting at 240 V, ETU860 electronic trip unit.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-7KQ32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2140-7KQ32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.8 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-7KQ32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860

Construction & Connection

3VA2140-7KQ32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-7KQ32-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2140-7KQ32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-7KQ32-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.1 in
Width (in)4.1 in
Depth (in)3.4 in

Product details

What the ratings mean for your panel

The Siemens SENTRON 3VA2140-7KQ32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 40 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. The 330 kA interrupting capacity at 240 V and 242 kA at 415 V means this breaker handles high-fault scenarios common in industrial distribution, safely clearing a short-circuit without upstream devices needing to trip. The ETU860 electronic trip unit gives you adjustable time-current curves (tr min 0.5 s to tr max 25 s, tsd max 0.5 s) so you can coordinate selectively downstream. Mounts in a standard panel footprint: 181 mm tall, 105 mm wide, 86 mm deep. The front face carries IP40 protection — fine for a clean indoor panel; keep it out of washdown zones. Communication function is built in (no external module required for basic integration), and the ground-fault monitoring works via summation current formation on the L-conductor — useful for detecting leakage in ungrounded or high-resistance-grounded systems.

Sizing and selectivity notes

The 40 A rating holds at every ambient point from 40 °C to 70 °C — no thermal derating curve to calculate. That simplifies panel design in warm enclosures or near other heat sources. The ETU860 release lets you set the short-time delay (tsd) up to 0.5 s, which gives downstream breakers time to clear a fault before this one opens, preserving uptime on unaffected feeders. Rated insulation voltage is 800 V. The interrupting capacity drops to 3.8 kA at 690 V.

Frequently asked questions

Does it drop into a panel designed for the 3VA2216-8JP42-0AA0?

No — the 3VA2216-8JP42-0AA0 is a different frame size and current rating. The 3VA2140-7KQ32-0AA0 has its own mounting footprint (181 x 105 x 86 mm) and requires separate panel cutout and bus connection planning.