Skip to main content
Siemens 3VA2140-7KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-7KQ42-0AA0 SENTRON MCCB, 40 A, 4-Pole, ETU86

MPN3VA2140-7KQ42-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 4-pole, 40 A, ETU860 electronic trip unit, 330 kA at 240 V interrupting rating, line protection version, IP40 front, communication capable.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-7KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2140-7KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W

Protection & Trip Unit

3VA2140-7KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor

Construction & Connection

3VA2140-7KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-7KQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2140-7KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-7KQ42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What the ratings mean for fit

The Siemens 3VA2140-7KQ42-0AA0 is a SENTRON molded case circuit breaker (MCCB) in the 3VA2 line-protection series, carrying 40 A continuous current flat across 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel thermal budgeting. The 4-pole construction with ETU860 electronic trip unit provides adjustable long-time, short-time, instantaneous, and ground-fault protection via summation current sensing on L+N conductors. Interrupting capacity reaches 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V — figures that place this breaker squarely in high-fault-duty distribution, not branch-circuit-only applications. The IP40 front rating means the breaker face is protected against solid objects over 1 mm but not against moisture; it belongs in a dry enclosure, not a washdown environment.

Panel integration and mounting

The breaker occupies 140 mm width × 181 mm height × 86 mm depth — a 4-pole MCCB footprint that fits standard Siemens 3VA2 mounting bases and busbar systems. The 86 mm depth (3.39 in) is the dimension from the mounting plane to the farthest rear projection; verify gland-plate clearance and door swing before committing the panel layout. The IP40 front face accepts standard padlockable handle mechanisms and auxiliary contact add-ons.

Communication and monitoring capability

The ETU860 trip unit supports communication functions and other measurement functions, which means it can report trip data, load profiles, and event logs over a digital bus when paired with the appropriate communication module — a feature set that matters for predictive maintenance and remote troubleshooting on a production line. The ground-fault monitoring version uses summation current formation on the L+N conductor, so it detects residual currents without a separate core-balance transformer.

Frequently asked questions

What is the interrupting rating of 3VA2140-7KQ42-0AA0 at 240 V?

The interrupting rating is 330 kA at 240 V, which qualifies it for high-fault-current distribution panels where fault levels exceed typical branch-circuit MCCB ratings.

Where can I buy 3VA2140-7KQ42-0AA0 and how is it quoted?

This part is sourced through independent industrial-automation distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

Does 3VA2140-7KQ42-0AA0 include ground-fault protection?

Yes, the ETU860 trip unit provides ground-fault monitoring via summation current formation on the L+N conductor, detecting residual currents without a separate external CT.

What is the depth of 3VA2140-7KQ42-0AA0?

The depth is 86 mm (3.39 in), measured from the mounting plane to the farthest rear projection.

MPN
3VA2140-7KQ42-0AA0