Skip to main content
Siemens 3VA2140-8KP36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-8KP36-0AA0 SENTRON MCCB, 40 A, 3-Pole, ETU85

MPN3VA2140-8KP36-0AA0
Active

Siemens SENTRON 3VA2140-8KP36-0AA0, 3-pole molded case circuit breaker, 40 A rated continuous current, ETU850 electronic trip unit, 440 kA breaking capacity at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2140-8KP36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2140-8KP36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.1.2 W

Protection & Trip Unit

3VA2140-8KP36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2140-8KP36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2140-8KP36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2140-8KP36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2140-8KP36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

SENTRON 3VA2140-8KP36-0AA0 — 40 A MCCB with ETU850 Trip Unit

The Siemens SENTRON 3VA2140-8KP36-0AA0 is a 3-pole molded case circuit breaker rated for 40 A continuous current, with an adjustable overcurrent release range from 60 A minimum to 480 A maximum — meaning the trip threshold can be dialed in across a wide band to match the actual load, not just the frame rating. It carries the ETU850 electronic trip unit, which provides adjustable long-time, short-time, instantaneous, and ground-fault protection curves — a step up from thermal-magnetic breakers for selectivity coordination in distribution panels. Breaking capacity is rated at 440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V — figures that cover most industrial service-entrance and sub-distribution fault levels without cascading upstream. The breaker includes a communication function onboard, enabling integration with higher-level monitoring or control systems — useful for remote trip indication and load management in automated lines.

Mounting and Panel Fit

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — the standard SENTRON 3VA2 frame footprint, so it retrofits into existing 3VA2 panel cutouts and bus-bar arrangements without re-drilling. Front-face protection is IP40, suitable for enclosed panel mounting where the breaker is not directly exposed to washdown or dust ingress. Operating temperature range spans -25 °C to 70 °C, with storage from -40 °C to 80 °C — adequate for unconditioned electrical rooms and most industrial enclosures.

Frequently asked questions

What trip unit does the 3VA2140-8KP36-0AA0 use?

It uses the ETU850 electronic trip unit, offering adjustable long-time, short-time, instantaneous, and ground-fault protection curves.

MPN
3VA2140-8KP36-0AA0