Skip to main content
Siemens 3VA2163-0HL46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-0HL46-0AA0 SENTRON MCCB, 63A, 4-Pole, ETU320

MPN3VA2163-0HL46-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 4-pole, 63 A rated continuous current, ETU320 electronic trip unit, 440 kA breaking capacity at 415 V AC, 690 V AC rated operating voltage, IP40 front protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-0HL46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-0HL46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.3.1 W
3VA2163-0HL46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-0HL46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-0HL46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-0HL46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-0HL46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

It carries a 63 A continuous current rating that holds flat from 40 °C through 70 °C — no derating needed across typical panel ambient temperatures — and a rated insulation voltage of 800 V, so it handles standard 400/480 VAC distribution without margin concerns.

The 4-pole frame delivers 440 kA breaking capacity at 415 V AC and 187 kA at 690 V AC — figures that put it in the high-interrupting category for industrial mains.

Trip unit and protection features

The N-conductor protection is configurable as OFF or 100 % of the phase rating.

Panel integration

Dimensions are 86 mm deep, 140 mm wide, and 181 mm tall — a 4-pole MCCB that fits standard Siemens 3VA2 panel cutouts and busbar systems. Maximum power loss is 3.1 W, which keeps heat rise manageable in a sealed enclosure.

Frequently asked questions

What is 3VA2163-0HL46-0AA0's listed depth?

The depth is 86 mm (3.39 in).

What is 3VA2163-0HL46-0AA0's listed width?

The width is 140 mm (5.51 in).

MPN
3VA2163-0HL46-0AA0