Siemens 3VA2163-0KQ46-0AA0 SENTRON MCCB, 63 A, 440 kA, 4-Pol

MPN3VA2163-0KQ46-0AA0
Active

Siemens SENTRON 3VA2163-0KQ46-0AA0, molded case circuit breaker, 4-pole, 63 A, 440 kA at 415 V AC, ETU860 electronic trip unit, line protection version.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-0KQ46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2163-0KQ46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.3.1 W
3VA2163-0KQ46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
3VA2163-0KQ46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-0KQ46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-0KQ46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-0KQ46-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2163-0KQ46-0AA0 is a 4-pole molded case circuit breaker (MCCB) in the 3VA2 frame, rated 63 A continuous current flat across 40 °C to 70 °C ambient — no derating needed in a warm enclosure. The ETU860 electronic trip unit gives adjustable overload and short-circuit protection, plus communication capability for power monitoring.

The 63 A rating is the assigned continuous current Iu — it carries the full load continuously without tripping, and the ETU860 release is adjustable, so you can set the actual trip point lower for cable protection. The 4-pole design covers three-phase plus neutral, with N-conductor protection adjustable from OFF to 40 %–160 % of the phase setting, which lets you coordinate with downstream devices on a 4-wire system.

Front IP40 protects against solid objects larger than 1 mm. ETU860 supports communication for power data to BMS or SCADA.

Frequently asked questions

What trip unit does 3VA2163-0KQ46-0AA0 use?

It uses the ETU860 electronic trip unit with adjustable overload and short-circuit settings, plus communication capability.

MPN
3VA2163-0KQ46-0AA0