Siemens SENTRON 3VA2 series, molded case circuit breaker (MCCB), 3-pole, 63 A, ETU310M electronic trip unit, 440 kA at 415 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-0MS32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-0MS32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.3.1 W
3VA2163-0MS32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-0MS32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-0MS32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-0MS32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-0MS32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2163-0MS32-0AA0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) designed for motor protection, rated 63 A continuous with an 800 V insulation voltage. Breaking capacity is 440 kA at 415 V AC and 187 kA at 690 V AC — enough headroom for high-fault installations like industrial substations or large motor control centers where selective coordination is required. The 3-pole design fits standard DIN-rail or panel-mount footprints. Rated current holds flat at 63 A across the full ambient range from 40 °C to 70 °C, so no derating is needed in a warm enclosure.

Dimensions & Panel Fit

The breaker measures 86 mm deep, 105 mm wide, and 181 mm high. These dimensions match the standard 3VA2 frame footprint; if you are replacing a 3VA2163-8HM32-0AA0 or similar sibling in the same frame size, the mounting hole pattern and bus-bar spacing are identical — no rewiring or panel modification needed.

Frequently asked questions

What is the breaking capacity of this MCCB?

The 3VA2163-0MS32-0AA0 has a breaking capacity of 440 kA at 415 V AC and 187 kA at 690 V AC, suitable for high-fault-current installations.

Will 3VA2163-0MS32-0AA0 drop into a panel specified around 3VA2163-8HM32-0AA0?

Yes, both are 3VA2 frame size with identical dimensions (86 x 105 x 181 mm) and the same 3-pole bus-bar spacing. The panel layout and wiring remain unchanged.

Where can I buy 3VA2163-0MS32-0AA0 and get current pricing?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

MPN
3VA2163-0MS32-0AA0