Skip to main content
Siemens 3VA2163-7MS32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MS32-0AJ0 SENTRON MCCB, 63 A, 3-pole, 330 k

MPN3VA2163-7MS32-0AJ0

Siemens SENTRON 3VA2163-7MS32-0AJ0, molded case circuit breaker, 3-pole, 63 A, starter protection design, 330 kA interrupting at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7MS32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MS32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2163-7MS32-0AJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-7MS32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-7MS32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7MS32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2163-7MS32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7MS32-0AJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

It's a 3-pole, 63 A frame with a compact footprint: 181 mm high, 105 mm wide, 86 mm deep, which fits standard panel layouts without forcing a wider enclosure. The interrupting ratings are serious — 330 kA at 240 V, 242 kA at 415 V, and still 187 kA at 500 V — so it can handle high-fault installations like transformer secondaries or large motor centers where upstream fault current is substantial. At 690 V it drops to 3.7 kA, which is typical for a 3-pole MCCB on a 690 V line; that's still adequate for most 690 V motor circuits but worth noting if you're close to the transformer.

Rated current and thermal performance — no derating up to 70 °C

That's unusual — most MCCBs start derating above 40 °C, but this one doesn't, so you can install it in a warm cabinet or near a motor without losing capacity. The maximum power loss is 4 W, which is low for a 63 A frame, so heat buildup in a dense panel is manageable.

Integration notes: auxiliary switches and trip alarm

That means you get remote status indication (open/closed) plus a separate signal for a trip event, without needing to add a separate auxiliary release. The basic switch supplied is 3VA2163-7MS32-0AA0, which is the same frame with a different accessory set. Panel cutout dimensions match the standard 3VA 3-pole footprint, so a panel designed for a 3VA2163-8HM32-0AA0 will accept this one without rewiring — same mounting hole pattern, same bus-bar spacing.

Frequently asked questions

What is the interrupting rating of 3VA2163-7MS32-0AJ0 at 240 V?

330 kA at 240 V, which covers most high-fault industrial panels. At 415 V it's 242 kA, at 500 V it's 187 kA, and at 690 V it's 3.7 kA.

Will 3VA2163-7MS32-0AJ0 drop into a panel designed for 3VA2163-8HM32-0AA0?

Yes, the physical footprint is identical — same 3-pole frame dimensions (181 x 105 x 86 mm) and same mounting pattern. The difference is in the accessories: this one has 2 auxiliary switches plus a trip alarm, while the -8HM32 variant has a different auxiliary release configuration.

What is the rated current of this MCCB at 60 °C?

63 A — the rating holds flat from 40 °C all the way up to 70 °C, so no derating needed in warm cabinets.

Where can I buy 3VA2163-7MS32-0AJ0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VA2163-7MS32-0AJ0