Skip to main content
Siemens 3VA2163-5HL32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HL32-0AJ0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2163-5HL32-0AJ0

Siemens SENTRON 3VA2, molded case circuit breaker, 3VA2163-5HL32-0AJ0, 63 A, 3-pole, line protection, 187 kA at 240 V, 121 kA at 415 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-5HL32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2163-5HL32-0AJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-5HL32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-5HL32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HL32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2163-5HL32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HL32-0AJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2163-5HL32-0AJ0 — SENTRON 3VA2 MCCB, 63 A, 3-Pole, Line Protection

The Siemens 3VA2163-5HL32-0AJ0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C, with no derating required within that window. This 3-pole unit is designed for line protection and carries a maximum breaking capacity of 187 kA at 240 VAC, 121 kA at 415 VAC and 440 VAC, 75.6 kA at 500 VAC, and 3.7 kA at 690 VAC — figures that define its fault-clearing capability at the point of common coupling. The adjustable thermal-magnetic trip unit covers a range from 95 A minimum to 756 A maximum, giving the specifying engineer headroom to coordinate with downstream branch protection. Rated insulation voltage is 800 V, and the breaker operates from -25 °C to 70 °C ambient, with storage limits from -40 °C to 80 °C.

The 187 kA at 240 V and 121 kA at 415 V place this MCCB in the high-interrupting category for 3VA2 frame sizes — suitable for installations with high available fault current, such as transformer secondaries or large motor control centers. Maximum power loss is 4 W, which keeps thermal contribution to the enclosure low.

Physical Integration and Auxiliary Wiring

A trip indicator is present for local visual fault indication. The underlying basic switch variant is 3VA21635HL320AA0, which means replacement of the switching mechanism alone is possible without swapping the entire chassis.

Frequently asked questions

What is the physical size of the 3VA2163-5HL32-0AJ0?

Width is 105 mm, height is 181 mm, and depth is 86 mm — a standard 3VA2 frame footprint.

Does this MCCB include auxiliary contacts?

Yes, it comes with 2 auxiliary switches plus 1 trip alarm switch (HP type) factory-installed.

MPN
3VA2163-5HL32-0AJ0