Siemens 3VA2163-5HL32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2163-5HL32-0CA0 MCCB, 63 A, 3-Pole, 187 k

MPN3VA2163-5HL32-0CA0

Siemens SENTRON 3VA2163-5HL32-0CA0, molded case circuit breaker, 3-pole, 63 A, 187 kA at 240 V, line protection, undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-5HL32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-5HL32-0AA0
3VA2163-5HL32-0CA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.6.5 W
3VA2163-5HL32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2163-5HL32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HL32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-5HL32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HL32-0CA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

At 415 V the rating drops to 121 kA, and at 690 V it falls to 4.25 kA — the arc energy scales with voltage, so the same mechanical gap can only extinguish so much. For a 63 A frame, this is an exceptionally high interrupting rating; most competitors in this frame size top out around 65–100 kA at 240 V. The ETU320 is a basic electronic trip unit — it provides long-time and short-time protection plus instantaneous, but no ground-fault or communication functions. That makes this breaker a fit for feeder or main protection where you need selectivity coordination downstream, not for branch circuits requiring ground-fault monitoring. The 63 A rating holds steady from 40 °C up to 50 °C ambient; above that it derates linearly to 53.55 A at 70 °C. If your panel runs hot (enclosed switchgear, solar combiner boxes), factor that derating into your load calculation.

The depth of 86 mm clears a standard enclosure with room for rear-mounted busbars.

Frequently asked questions

What trip unit does this MCCB use?

The ETU320 electronic trip unit, which provides long-time, short-time, and instantaneous protection. It does not include ground-fault monitoring or communication functions.