Skip to main content
Siemens 3VA2163-5HL32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HL32-0DA0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA2163-5HL32-0DA0

Siemens SENTRON molded case circuit breaker, 3VA2163-5HL32-0DA0, 3-pole line protection, 63 A continuous, 187 kA interrupting at 240 V, undervoltage release included.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-5HL32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635HL320AA0
3VA2163-5HL32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.6.5 W
3VA2163-5HL32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-5HL32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HL32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-5HL32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HL32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2163-5HL32-0DA0 — SENTRON MCCB, 63 A, Line Protection with UVR

The Siemens SENTRON 3VA2163-5HL32-0DA0 is a 3-pole molded case circuit breaker (MCCB) designed for line protection, carrying a continuous current rating of 63 A across the full ambient temperature range from 40 °C to 70 °C without derating — a practical advantage for densely packed panels where heat buildup is a concern. Its interrupting capacity hits 187 kA at 240 V AC, dropping to 121 kA at 415 V and 440 V, then 75.6 kA at 500 V, and 3.7 kA at 690 V — the high 240 V figure gives substantial fault-clearing headroom on 208/240 V distribution, while the 690 V rating confirms it's not intended for 690 V motor circuits (use a 3VA2 with higher 690 V SCCR for that). Mounts in a standard panel footprint: 105 mm wide, 181 mm tall, 86 mm deep — dimensions shared across the 3VA2 frame, meaning a panel cut for a sibling like 3VA2163-8HM32-0AA0 accepts this unit without rework.

Sourcing & Lifecycle — Active Production, Quoted to Order

The part carries a rated insulation voltage of 800 V, power loss of 6.5 W maximum, and an operating temperature range of -25 °C to 70 °C.

Panel Fit & Integration — Same Frame as 3VA2163-8HM32-0AA0

The 3VA2163-5HL32-0DA0 shares the same 105 mm width, 181 mm height, and 86 mm depth as the 3VA2163-8HM32-0AA0 — they are the same mechanical frame. A panel drilled for the -8HM32 variant accepts this unit with no busbar or mounting-footprint changes. If your BOM specifies UVR functionality, this is the direct fit; if not, verify the trip coordination study before swapping.

Frequently asked questions

Where can I buy 3VA2163-5HL32-0DA0 and get current pricing?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

Will 3VA2163-5HL32-0DA0 drop into a panel specified for 3VA2163-8HM32-0AA0?

Yes — both share the same 105 mm width, 181 mm height, and 86 mm depth, so the mechanical fit is identical. The difference is the trip unit: this -5HL32 includes an undervoltage release and is set for line protection, while the -8HM32 uses a different trip curve. Verify the trip coordination before substituting.

What compliance documentation is available for 3VA2163-5HL32-0DA0?

As a Siemens SENTRON MCCB, it carries CE marking for the European market and is designed to meet IEC 60947-2. Documentation including the declaration of conformity and the product datasheet is available upon request with an RFQ.

MPN