Skip to main content
Siemens 3VA2163-5HL32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HL32-0DH0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA2163-5HL32-0DH0

Siemens SENTRON 3VA2163-5HL32-0DH0, molded case circuit breaker, 3-pole, 63 A, ETU320 release, 187 kA at 240 V, 121 kA at 415 V, undervoltage release, 2 aux + 1 alarm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-5HL32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2163-5HL32-0DH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.6.5 W
3VA2163-5HL32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2163-5HL32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HL32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2163-5HL32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HL32-0DH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2163-5HL32-0DH0 is a 3-pole molded case circuit breaker rated 63 A continuous current at 40 °C, with an ETU320 electronic trip unit configured for line protection. The 187 kA breaking capacity at 240 V and 121 kA at 415 V means it can safely interrupt high-fault currents on the secondary side of a distribution transformer or at a main panelboard — the kind of fault level you see near a utility service entrance. At 690 V the rating drops to 4.25 kA, so this breaker is sized for low-voltage distribution, not 690 V motor circuits.

The 63 A rating holds flat up to 50 °C; above that it derates to 60.6375 A at 55 °C, 58.275 A at 60 °C, 55.9125 A at 65 °C, and 53.55 A at 70 °C. If the breaker lives in a crowded enclosure with other heat sources, use the 60 °C column for continuous-load sizing — the 58.275 A figure is the practical limit for a 63 A feeder in a warm panel. The 86 mm depth, 105 mm width, and 181 mm height fit the standard SENTRON 3VA frame footprint; it mounts on a DIN rail or screws directly to a backplate.

Auxiliary and trip configuration

The UVR drops the breaker if control voltage falls below the dropout threshold — standard for emergency-stop or undervoltage protection schemes. The trip alarm switch signals a fault condition independently of the aux contacts, which is useful for remote SCADA alarming. The basic switch module is order code 3VA2163-5HL32-0AA0; the integrated auxiliary trip module is 3VA9608-0BB25.

Frequently asked questions

What is the breaking capacity of this MCCB at different voltages?

187 kA at 240 V, 121 kA at 415 V and at 440 V, 79 kA at 500 V, and 4.25 kA at 690 V.

What is the closest functional second-source to 3VA2163-5HL32-0DH0?

The 3VA2116-5HL32-0AK0 is the closest peer within the same 3VA2 frame family — same 63 A rating, same ETU320 release, same 3-pole form factor. The difference is in the auxiliary contact configuration and the undervoltage release option; verify your control wiring before substituting.

Will 3VA2163-5HL32-0DH0 drop into a panel specified around 3VA1112-5EF32-0CA0?

No — the 3VA1112 is a 1-pole frame with different mounting dimensions and a lower breaking capacity. The 3VA2163 is a 3-pole breaker; it requires the larger 3VA2 footprint and a three-phase bus connection.

Where can I buy 3VA2163-5HL32-0DH0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2163-5HL32-0DH0