Skip to main content
Siemens 3VA2163-5HL32-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HL32-0KC0 SENTRON MCCB, 63 A, 3-Pole

MPN3VA2163-5HL32-0KC0

Siemens SENTRON 3VA2, molded case circuit breaker, 3-pole, 63 A continuous, adjustable thermal-magnetic trip 95–756 A, breaking capacity 187 kA at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5HL32-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2163-5HL32-0KC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5HL32-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-5HL32-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5HL32-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2163-5HL32-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5HL32-0KC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers on the line

The 3VA2163-5HL32-0KC0 is a Siemens SENTRON 3VA2 molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C through 70 °C — no derating needed across that band. The adjustable thermal-magnetic trip unit covers 95 A minimum to 756 A maximum, so you set it to the actual load, not the frame. Breaking capacity runs 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V; that 187 kA figure at 240 V handles high-fault utility feeds without cascading upstream. The 3-pole design is line-protection configured — no communication module, no ground-fault monitoring, no undervoltage release on this variant. It ships with a shunt trip (STL) release and two auxiliary switches HQ. The internal basic switch is order code 3VA21635HL320AA0.

Panel fit and physical integration

Dimensions are 105 mm wide, 181 mm high, 86 mm deep — a standard 3-pole MCCB footprint for DIN-rail or panel-mount installation. Maximum power loss is 4 W, so heat dissipation is minimal inside the enclosure. Operating temperature range is -25 °C to 70 °C; storage from -40 °C to 80 °C.

Trip indicator and auxiliary release detail

This variant has no trip indicator and no undervoltage release. The auxiliary release is a shunt trip (STL) — used for remote tripping via a control signal. The two auxiliary switches HQ provide status feedback for the breaker position.

Frequently asked questions

Where can I buy 3VA2163-5HL32-0KC0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing at the time of order.

What is the breaking capacity of 3VA2163-5HL32-0KC0 at different voltages?

Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The 187 kA figure at 240 V is suitable for high-fault utility feeds.

What is the continuous current rating and trip range of this MCCB?

Continuous current rating is 63 A from 40 °C through 70 °C (–). The adjustable thermal-magnetic trip unit covers 95 A minimum to 756 A maximum.

What are the physical dimensions of 3VA2163-5HL32-0KC0?

Width is 105 mm, height is 181 mm, depth is 86 mm.

MPN