Skip to main content
Siemens 3VA2163-5HL32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2163-5HL32-0KL0 MCCB, 63A, 187kA at 240V

MPN3VA2163-5HL32-0KL0

Siemens SENTRON 3VA series, molded case circuit breaker, 3VA2163-5HL32-0KL0, 3-pole, 63 A continuous, 187 kA at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5HL32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2163-5HL32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5HL32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-5HL32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5HL32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2163-5HL32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5HL32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries and where it fits

The Siemens SENTRON 3VA2163-5HL32-0KL0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to the 70 °C operating maximum. That flat thermal curve simplifies panel sizing in warm enclosures or near other heat sources. Its interrupting ratings climb to 187 kA at 240 V, drop to 121 kA at 415 V and 440 V, then to 75.6 kA at 500 V, and 3.7 kA at 690 V. The 187 kA figure at 240 V tells you this breaker handles high available fault current on 240 V distribution — typical for large transformer-fed panels or industrial service entrances where the upstream transformer is close-coupled.

Line protection design with integrated accessories

This variant is configured for line protection — the base design of the product is protection of the feeder or branch circuit, not motor or generator protection. It ships with a shunt trip release (STL) and an auxiliary switch block carrying 2 auxiliary switches plus 1 trip alarm switch plus 1 electrical alarm switch. The trip indicator and voltage trigger are present; undervoltage release and ground-fault monitoring are not fitted on this order code. Dimensions are 105 mm wide, 181 mm high, 86 mm deep — a standard 3-pole MCCB footprint that fits SENTRON panel-mounting accessories and busbar systems. The 4 W maximum power loss at rated current is low enough that internal cabinet heating from the breaker itself is negligible in a ventilated enclosure.

Frequently asked questions

What are the key ratings for 3VA2163-5HL32-0KL0?

63 A continuous current (no derating from 40 °C to 70 °C), 3-pole, interrupting capacity of 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. Dimensions are 105 mm wide × 181 mm high × 86 mm deep.

Where can I buy 3VA2163-5HL32-0KL0?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quotation to confirm current availability and pricing.

What is the continuous current rating and does it derate with temperature?

Rated 63 A continuous, and it holds that rating from 40 °C through 70 °C ambient — no derating required across the full operating temperature range.

MPN
3VA2163-5HL32-0KL0