Siemens 3VA2163-5HL36-0DA0 SENTRON MCCB, 63 A, 3-Pole, ETU32

MPN3VA2163-5HL36-0DA0

Siemens SENTRON 3VA2163-5HL36-0DA0, molded case circuit breaker, 3-pole, 63 A rated continuous current, ETU320 electronic trip unit, undervoltage release, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-5HL36-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-5HL36-0AA0
3VA2163-5HL36-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.6.5 W
3VA2163-5HL36-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2163-5HL36-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HL36-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-5HL36-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HL36-0DA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Siemens SENTRON 3VA2163-5HL36-0DA0 — 63 A MCCB with ETU320 and Undervoltage Release

The Siemens SENTRON 3VA2163-5HL36-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current (Iu) at 40 °C, with an ETU320 electronic trip unit and an integrated undervoltage release (UVR). Rated insulation voltage is 800 V, and the breaker delivers interrupting ratings of 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V — covering most industrial distribution fault levels. The ETU320 is a basic electronic trip unit for line protection (overload and short-circuit), with no communication function, no phase-failure detection, and no ground-fault monitoring — a straightforward thermal-magnetic replacement in electronic form.

Dimensions are 105 mm wide × 181 mm high × 86 mm deep — a standard 3-pole MCCB footprint for Siemens 3VA2 frames, mounting on a DIN rail or panel baseplate. The breaker accepts a separate auxiliary contact (not included; order 3VA9608-0BB25 separately) and the undervoltage release is factory-integrated, so no field wiring of the UVR coil is required.

Rated 63 A continuous from 40 °C through 50 °C; derates linearly to 60.6 A at 55 °C, 58.3 A at 60 °C, 55.9 A at 65 °C, and 53.6 A at 70 °C — account for enclosure ambient when sizing. Maximum power loss is 6.5 W.

Frequently asked questions

Does 3VA2163-5HL36-0DA0 include an undervoltage release?

Yes, it has a factory-integrated undervoltage release (UVR) as the auxiliary release design.

What trip unit does 3VA2163-5HL36-0DA0 use?

The ETU320 electronic trip unit, configured for line protection (overload and short-circuit) with no communication, phase-failure detection, or ground-fault monitoring.