Skip to main content
Siemens 3VA2163-5HL36-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2163-5HL36-0DH0 MCCB, 63 A, 3-Pole, 187 k

MPN3VA2163-5HL36-0DH0

Siemens SENTRON molded case circuit breaker, 3VA2163-5HL36-0DH0, 63 A continuous, 3-pole, adjustable thermal-magnetic trip range 95–756 A, 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-5HL36-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2163-5HL36-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.6.5 W
3VA2163-5HL36-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-5HL36-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HL36-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2163-5HL36-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HL36-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2163-5HL36-0DH0 is a 3-pole molded case circuit breaker rated for 63 A continuous current at 40–70 °C without derating — the full thermal curve holds flat across that span, so no re-rating needed for warm enclosures. The adjustable thermal-magnetic trip covers 95 A minimum to 756 A maximum, which gives you a wide coordination window for downstream feeders or motor branch circuits. Breaking capacity runs 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the 690 V figure is low, so confirm system voltage before committing the BOM line.

Design and integrated accessories

The UVR drops the breaker on loss of control voltage — standard for safety disconnects or emergency-off circuits. The supplied basic switch is 3VA21635HL360AA0, so replacement or spare-parts ordering is straightforward. No ground-fault monitoring or communication module is fitted; those are separate add-ons if needed.

The 86 mm depth fits standard 200 mm deep enclosures; verify door clearance if a rotary handle or extended shaft is used.

Frequently asked questions

Who supplies 3VA2163-5HL36-0DH0 and how is it quoted for volume purchases?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is the breaking capacity of 3VA2163-5HL36-0DH0 at 415 V?

121 kA at 415 V, same as at 440 V.

Does this MCCB include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) as standard.

MPN