Siemens 3VA2163-5HL36-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HL36-0HC0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA2163-5HL36-0HC0

Siemens SENTRON 3VA2163-5HL36-0HC0, 3-pole molded case circuit breaker, 63 A rated continuous current at 40 °C, 187 kA breaking capacity at 240 V AC, ETU320 electronic trip unit, shunt trip (STL), 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5HL36-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-5HL36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2163-5HL36-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5HL36-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320

Construction & Connection

3VA2163-5HL36-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5HL36-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2163-5HL36-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5HL36-0HC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

63 A MCCB with 187 kA interrupting capacity

The Siemens 3VA2163-5HL36-0HC0 is a 3-pole SENTRON molded case circuit breaker rated for 63 A continuous current at 40 °C ambient, with a breaking capacity of 187 kA at 240 V AC. That interrupting rating drops to 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V — so the voltage class you're protecting determines which fault level this breaker can clear. It carries an ETU320 electronic trip unit and a built-in shunt trip (STL) for remote opening, plus two HQ auxiliary switches for status feedback.

Thermal derating and operating range

Rated continuous current holds at 63 A from 40 °C through 50 °C ambient. Above that it derates: 60.6375 A at 55 °C, 58.275 A at 60 °C, 55.9125 A at 65 °C, and 53.55 A at 70 °C. Operating ambient range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The 4 W maximum power loss matters for enclosure heat budgeting in a sealed panel.

Line protection configuration

This variant is configured for line protection — no undervoltage release, no ground-fault monitoring, no phase-failure detection, no communication module. The ETU320 electronic trip unit handles overload and short-circuit protection with adjustable settings. The shunt trip (STL) allows a remote signal to trip the breaker, useful for emergency-stop circuits or supervisory shutdown. Two HQ auxiliary switches provide normally-open/normally-closed contacts for panel indication or PLC inputs.

Mechanical footprint and endurance

Dimensions are 105 mm wide, 181 mm high, 86 mm deep — standard 3-pole MCCB footprint for panel mounting. The 20,000-cycle mechanical endurance is typical for this class; the breaker is designed for fixed installation, not frequent switching duty. Rated insulation voltage is 800 V.

Frequently asked questions

Where can I buy 3VA2163-5HL36-0HC0?

This part is sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time.

What is the breaking capacity of this MCCB at different voltages?

Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V.

What trip unit and accessories does 3VA2163-5HL36-0HC0 include?

It includes an ETU320 electronic trip unit, a built-in shunt trip (STL) for remote tripping, and two HQ auxiliary switches. No undervoltage release, ground-fault monitor, or communication module.

What are the physical dimensions of this breaker?

Width is 105 mm, height is 181 mm, depth is 86 mm.

MPN
3VA2163-5HL36-0HC0