Skip to main content
Siemens 3VA2163-5HL36-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HL36-0KC0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2163-5HL36-0KC0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2163-5HL36-0KC0, 63 A, 3-pole, 187 kA at 240 V, line protection, with shunt trip and 2 auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-5HL36-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2163-5HL36-0KC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-5HL36-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-5HL36-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HL36-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2163-5HL36-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HL36-0KC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2163-5HL36-0KC0 is a SENTRON molded case circuit breaker rated for continuous 63 A across its full operating temperature range of -25 °C to 70 °C, with no derating needed up to 70 °C. The 3-pole design includes a factory-fitted shunt trip (STL) and two auxiliary switches (HQ), so it arrives ready for remote tripping and status feedback without extra wiring.

This MCCB delivers 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The steep drop at 690 V is typical for a 63 A frame; if your fault current at 690 V exceeds 3.7 kA, you need a higher-rated frame or a current-limiting upstream device. At 415 V the 121 kA rating covers most industrial service entrances and large sub-distribution boards.

Frequently asked questions

Where can I buy 3VA2163-5HL36-0KC0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — no stock or price figures are listed here.

What is the closest functional second-source to 3VA2163-5HL36-0KC0?

The 3VA2116-5HL32-0AK0 is a smaller-frame sibling (16 A vs 63 A) and will not drop into the same panel without rewiring the busbars and adjusting the mounting. For a 63 A line-protection MCCB with shunt trip, the 3VA2163-5HL36-0KC0 is the correct fit.

What compliance documentation does Siemens provide for this MCCB?

Siemens typically supplies RoHS and REACH declarations, plus IEC/UL certification documentation for the SENTRON 3VA2 series. Specific certificates are available on request at quote time.

MPN
3VA2163-5HL36-0KC0