Siemens 3VA2163-5HL42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HL42-0AA0 SENTRON MCCB, 63 A, 4-Pole, 187 k

MPN3VA2163-5HL42-0AA0
Active

Siemens SENTRON 3VA2163-5HL42-0AA0, molded case circuit breaker, 4-pole, 63 A, ETU320 electronic trip, 187 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5HL42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2163-5HL42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5HL42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-5HL42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5HL42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2163-5HL42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5HL42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2163-5HL42-0AA0 — 63 A MCCB, Line Protection, ETU320 Trip

The Siemens SENTRON 3VA2163-5HL42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for 63 A continuous current, designed for line protection in distribution panels. It carries an interrupting capacity of 187 kA at 240 V AC, derating to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — so at typical 400 V class supply voltages it clears faults up to 121 kA without cascading upstream. The electronic trip unit (ETU320) provides adjustable overload and short-circuit protection curves, making this breaker suitable for feeder circuits where coordination with downstream devices is required. Rated insulation voltage is 800 V, and the breaker dissipates a maximum of 4 W at rated load — negligible heat for panel thermal budgeting. The front face carries IP40 protection, meaning it is protected against tools and small solid objects but not sealed against moisture; mount it inside a suitable enclosure for washdown or outdoor environments. Operating temperature range spans -25 °C to 70 °C, with storage from -40 °C to 80 °C. Dimensions are 181 mm height, 140 mm width, and 86 mm depth — a standard footprint for a 4-pole frame in this class. The breaker does not include an undervoltage release, ground-fault monitoring, or communication function; it is a straight line-protection device with the ETU320 as the only intelligent element.

Panel Integration & Mounting

The 3VA2163-5HL42-0AA0 mounts on a DIN rail or can be screw-fixed to a backplate. The 140 mm width occupies roughly 5.5 inches of rail space for the 4-pole frame. Spring-cage terminals accept copper conductors sized for the 63 A rating; verify lug torque per the installation instructions. The IP40 front face means the breaker is suitable for enclosed panel mounting — no additional gasketing required inside a standard IP54 or higher enclosure.

Frequently asked questions

What is the interrupting capacity of 3VA2163-5HL42-0AA0 at 415 V?

At 415 V AC, the interrupting capacity is 121 kA.

What trip unit does this MCCB use?

It uses the ETU320 electronic overcurrent release, which provides adjustable overload and short-circuit protection.

Where can I buy 3VA2163-5HL42-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2163-5HL42-0AA0