It carries an adjustable thermal-magnetic or electronic trip range from a minimum of 95 A up to a maximum of 756 A, meaning the trip threshold can be field-set to match the protected conductor or load without swapping the breaker frame. Breaking capacity is rated at 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the 240 V figure covers the highest fault-current scenario typical in North American 277/480 V panelboards, while the 415/440 V ratings handle European 400 V industrial mains.

Siemens SENTRON 3VA2163-5HL46-0AA0 MCCB, 63 A, 4-Pole, 187 k
MPN3VA2163-5HL46-0AA0
Active
Siemens SENTRON 3VA2163-5HL46-0AA0, molded case circuit breaker, 4-pole, 63 A rated continuous current, ETU320 electronic trip unit, breaking capacity 187 kA at 240 V AC.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Parameter | Value |
|---|---|
| Number of poles | 4 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 63 A |
| Current at 45 °C | 63 A |
| Current at 50 °C | 63 A |
| Current at 55 °C | 63 A |
| Current at 60 °C | 63 A |
| Current at 65 °C | 63 A |
| Current at 70 °C | 63 A |
| Switching capacity class | M |
| Breaking capacity at 240 V | 187 kA |
| Breaking capacity at 415 V | 121 kA |
| Breaking capacity at 440 V | 121 kA |
| Breaking capacity at 500 V | 75.6 kA |
| Breaking capacity at 690 V | 3.7 kA |
| Power loss, max. | 4 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | ETU320 |
| Overcurrent protection function | LI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
| Parameter | Value |
|---|---|
| Main circuit connection type | double-sided box terminal |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | No |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | No |
| Measurement function | No |
| Motor drive option | Yes |
| Auxiliary CO contacts | 0 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 25 000 |
| Height | 181 mm |
| Width | 140 mm |
| Depth | 86 mm |
| Height (in) | 7.13 in |
| Width (in) | 5.51 in |
| Depth (in) | 3.39 in |
Product details
Frequently asked questions
What trip unit does 3VA2163-5HL46-0AA0 use?
It uses the ETU320 electronic trip unit, which provides adjustable overload and short-circuit protection curves for selective coordination.
MPN
3VA2163-5HL46-0AA0