Skip to main content
Siemens 3VA2163-5HN32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HN32-0AF0 SENTRON MCCB, 63 A, 3-pole, ETU35

MPN3VA2163-5HN32-0AF0

Siemens SENTRON 3VA2, Molded case circuit breaker, 3VA2163-5HN32-0AF0, 63 A, 3-pole, ETU350, 187 kA at 240 V, 121 kA at 415 V, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-5HN32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2163-5HN32-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.4 W
3VA2163-5HN32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2163-5HN32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HN32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2163-5HN32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HN32-0AF0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Siemens SENTRON 3VA2163-5HN32-0AF0 — 63 A MCCB with ETU350 trip unit

The Siemens 3VA2163-5HN32-0AF0 is a SENTRON 3VA2 molded case circuit breaker rated for a continuous current Iu of 63 A across a 40 °C to 50 °C ambient, with a slight derating curve starting at 55 °C (60.6 A) down to 53.6 A at 70 °C. Breaking capacity is the headline number here: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V. The auxiliary contact set is 1 NO + 1 NC with a trip alarm switch (HQ designation), giving remote status and trip indication without needing a separate module.

Dimensions are 105 mm wide, 181 mm tall, 86 mm deep — standard 3-pole MCCB footprint for the SENTRON 3VA2 family. The 86 mm depth matters for shallow enclosures; check gland-plate clearance if you're fitting it into a retrofit panel where the backplane depth is tight.

Frequently asked questions

What are the key ratings for this MCCB?

Rated continuous current Iu is 63 A, breaking capacity is 187 kA at 240 V AC and 121 kA at 415 V AC, with an ETU350 electronic trip unit for LSI protection curves.

What is the depth of this breaker?

The depth is 86 mm, with a width of 105 mm and height of 181 mm.

Where can I buy 3VA2163-5HN32-0AF0 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing at the time of order.

MPN
3VA2163-5HN32-0AF0