Skip to main content
Siemens 3VA2163-5HN32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HN32-0JH0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA2163-5HN32-0JH0

Siemens SENTRON 3VA2163-5HN32-0JH0, molded case circuit breaker, 3-pole, 63 A, 187 kA at 240 V, 121 kA at 415 V, line protection, with shunt trip (STL) and 2 aux + 1 trip alarm switch HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5HN32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635HN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2163-5HN32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5HN32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-5HN32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5HN32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2163-5HN32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5HN32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2163-5HN32-0JH0 — 63 A MCCB for Line Protection

The Siemens 3VA2163-5HN32-0JH0 is a SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous current across the full 40–70 °C ambient range — no derating needed in a warm panel. It carries a 187 kA interrupting capacity at 240 V and 121 kA at 415 V, which gives solid SCCR headroom for most industrial distribution boards without cascading upstream. The breaker is designed for line protection (cable/feeder), not motor protection, so the thermal-magnetic curve is set for conductor overload and short-circuit clearing. This 3-pole unit ships with a factory-installed shunt trip (STL) release and a 2 auxiliary + 1 trip alarm switch HQ configuration — that covers remote tripping and status feedback without adding a separate accessory kit. The shunt trip lets a safety PLC or E-stop circuit kill the breaker remotely, which is a common requirement on automated lines.

Panel Fit and Mounting

The breaker footprint is 105 mm wide by 181 mm tall by 86 mm deep — a standard SENTRON 3VA2 frame size that fits existing 3VA panel cutouts and busbar systems. No adapter plate needed for a direct swap into a Siemens switchboard or distribution panel that already takes 3VA2 breakers. The 4 W maximum power loss is low enough that adjacent units in a multi-breaker lineup won't force a derating derate under normal loading.

Frequently asked questions

What are the key ratings for this MCCB?

It is a 3-pole 63 A breaker with 187 kA interrupting at 240 V, 121 kA at 415 V, and 75.6 kA at 500 V. Continuous current holds at 63 A from 40 °C up to 70 °C ambient.

What is the depth of this breaker?

The listed depth is 86 mm (3.39 in).

Where can I buy 3VA2163-5HN32-0JH0 and how is it quoted?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — both are confirmed at quote time, not on a static listing.

Does this breaker include a shunt trip and auxiliary contacts?

Yes, it comes with a shunt trip (STL) release and a 2 auxiliary + 1 trip alarm switch HQ configuration factory-installed.

MPN