Skip to main content
Siemens 3VA2163-5HN36-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HN36-0HC0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA2163-5HN36-0HC0

Siemens SENTRON 3VA2163-5HN36-0HC0, molded case circuit breaker, 3-pole, 63 A, breaking capacity 187 kA at 240 V, 121 kA at 415 V, with shunt trip and 2 auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-5HN36-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2163-5HN36-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-5HN36-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-5HN36-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HN36-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2163-5HN36-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HN36-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Line protection MCCB with shunt trip and auxiliary switches

Its 3-pole design carries a breaking capacity of 187 kA at 240 V AC, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V, giving you selectivity headroom for high-fault installations like transformer secondaries or large motor control centers. The unit includes an integrated shunt trip (STL) and two auxiliary switches (HQ), so it arrives ready for remote tripping and status feedback without adding accessory modules.

The depth of 86 mm (3.39 in) leaves clearance for rear-access wiring in enclosures with shallow gland plates. Maximum power loss is 4 W, so heat buildup in a sealed cabinet is minimal.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-5HN36-0HC0?

Submit an RFQ through this listing; availability and current pricing are confirmed at quote time through independent distribution channels.

What are the key ratings of this MCCB?

Continuous current is 63 A (no derating up to 70 °C), breaking capacity is 187 kA at 240 V, 121 kA at 415/440 V, and 75.6 kA at 500 V. It is a 3-pole line-protection device with a shunt trip and two auxiliary switches.

What are the physical dimensions of 3VA2163-5HN36-0HC0?

Width 105 mm (4.13 in), height 181 mm (7.13 in), depth 86 mm (3.39 in).

MPN
3VA2163-5HN36-0HC0