Skip to main content
Siemens 3VA2163-5JQ32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5JQ32-0AH0 SENTRON MCCB, 63 A, 187 kA

MPN3VA2163-5JQ32-0AH0

Siemens SENTRON 3VA2163-5JQ32-0AH0, molded case circuit breaker, 3-pole, 63 A rated continuous current, ETU560 electronic trip unit, 187 kA at 240 V, 121 kA at 415 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5JQ32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-5JQ32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2163-5JQ32-0AH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5JQ32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560

Construction & Connection

3VA2163-5JQ32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5JQ32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2163-5JQ32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5JQ32-0AH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2163-5JQ32-0AH0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current, with an ETU560 electronic trip unit for line protection. Its 187 kA breaking capacity at 240 V handles high-fault-current scenarios typical of large distribution panels or transformer secondaries. The 121 kA rating at 415 V and 440 V covers most European industrial mains, while the 4.25 kA at 690 V suits lower-fault installations like motor control centers. This MCCB carries a 63 A rating across ambient temperatures from 40 °C to 50 °C, with a gentle derating curve starting at 55 °C (60.6 A) down to 53.6 A at 70 °C — useful for panels with limited airflow or high internal heat rise. The 800 V rated insulation voltage (Ui) gives headroom for 690 V systems.

Lifecycle and sourcing

The basic switch variant (without trip unit) is order code 3VA2163-5JQ32-0AA0, which may be relevant for replacement of the switching mechanism alone.

Integration and mounting

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard SENTRON 3VA2 frame size that fits Siemens distribution panels and most third-party enclosures with compatible mounting cutouts. The front face carries IP40 protection, suitable for enclosed panel mounting where dust ingress is controlled. The auxiliary contact configuration (2 auxiliary switches + 1 trip alarm switch HQ) provides status feedback for PLC or SCADA systems. Communication function is built in, supporting integration into higher-level monitoring without an external module.

Trip unit and protection features

The ETU560 electronic trip unit offers adjustable protection curves for line protection. A trip indicator is present for quick fault identification during troubleshooting. No undervoltage release or phase failure detection is fitted on this variant; those functions would require a different order code or add-on module. Maximum power loss is 4 W, which is low enough to avoid significant heat buildup in a densely packed panel. The operating temperature range spans -25 °C to 70 °C, with storage from -40 °C to 80 °C.

Frequently asked questions

What is the breaking capacity of 3VA2163-5JQ32-0AH0 at different voltages?

187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V. These ratings cover most industrial distribution and motor control applications.

What trip unit does this MCCB use?

It uses the ETU560 electronic trip unit, which provides adjustable protection curves for line protection. A trip indicator is included for fault identification.

Where can I buy 3VA2163-5JQ32-0AH0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

MPN
3VA2163-5JQ32-0AH0