Siemens 3VA2163-5JQ32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5JQ32-0HC0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2163-5JQ32-0HC0

Siemens SENTRON 3VA2163-5JQ32-0HC0, molded case circuit breaker, 3-pole, 63 A rated, line protection design, 187 kA breaking at 240 V, with communication function and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5JQ32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635JQ320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2163-5JQ32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5JQ32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2163-5JQ32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5JQ32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2163-5JQ32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5JQ32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what it does

The Siemens 3VA2163-5JQ32-0HC0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection — meaning its primary job is protecting cable and busbar from overloads and short circuits in a distribution panel, not motor or generator protection. It's a 3-pole unit with a full-scale current rating of 63 A, and it carries an overload setting range from 95 A minimum to 756 A maximum, so the trip threshold is field-adjustable across a wide band to match the downstream conductor ampacity.

Breaking capacity — what the numbers mean for your fault level

The interrupting rating is the spec that decides whether this breaker clears a fault or welds shut. At 240 V it's rated for 187 kA — that's a very high figure, typical for a large-frame MCCB feeding a main switchboard or a high-fault industrial panel. At 415 V and 440 V it holds at 121 kA, then drops to 75.6 kA at 500 V, and falls off sharply to 3.7 kA at 690 V. That steep drop at 690 V means this breaker is not intended for 690 V main service; it's a 480 V class device with a generous safety margin for most North American and European 400 V distribution.

Thermal rating — flat across the operating range

The 63 A rating holds flat from 40 °C through 70 °C ambient — no derating needed up to that ceiling. That's unusual for an MCCB; many competitors start derating above 40 °C. The operating temperature floor is -25 °C, storage range -40 °C to 80 °C. Maximum power loss is 4 W, which is low enough that ventilation spacing in the panel is not a concern for this breaker alone.

Auxiliary and communication options

This variant ships with two auxiliary switches (HQ type) and a shunt trip release (STL) for remote tripping. It also includes a communication function via a plug-in module.

Physical fit and panel integration

Dimensions are 105 mm wide, 181 mm tall, 86 mm deep — a standard 3-pole MCCB footprint that fits most Siemens SENTRON distribution panels and third-party enclosures with a 105 mm cutout. The depth of 86 mm means it will clear a typical 200 mm deep enclosure door without interference. Mounting is via screw-clamp terminals on the line and load sides; no DIN-rail clip on this frame class.

Frequently asked questions

Does this breaker include a shunt trip or undervoltage release?

It includes a shunt trip release (STL) for remote tripping, but no undervoltage release. The trip indicator is also absent.

MPN
3VA2163-5JQ32-0HC0