Siemens 3VA2163-5JQ36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5JQ36-0AA0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2163-5JQ36-0AA0
Active

Siemens SENTRON 3VA2163-5JQ36-0AA0, molded case circuit breaker, 3-pole, 63 A continuous, 187 kA at 240 V, line protection, with communication function and ground-fault monitoring.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-5JQ36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-5JQ36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-5JQ36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2163-5JQ36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5JQ36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-5JQ36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5JQ36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2163-5JQ36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to that ceiling.

This MCCB delivers 187 kA at 240 V, 121 kA at 415 V and at 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The 187 kA figure at 240 V covers high-fault utility feeds in North American panels; the 121 kA at 415 V handles the common industrial fault level in IEC 60947-2 installations. At 690 V the capacity drops to 3.7 kA — adequate for most 690 V motor circuits but verify against your system's prospective short-circuit current.

The 105 mm width matches the common 4-module (4 x 27 mm) DIN-rail spacing used in SENTRON distribution boards, so it drops into an existing panel without re-drilling the mounting plate.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-5JQ36-0AA0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

Will 3VA2163-5JQ36-0AA0 drop into a panel that was specified around 3VA2163-8HM32-0AA0 without rewiring?

Both are 3-pole SENTRON MCCBs in the same 105 mm width footprint, so the mechanical fit is identical. The 5JQ36 variant includes communication and ground-fault monitoring features that the 8HM32 may lack — verify the auxiliary wiring and control voltage requirements before swapping.

What compliance documentation does this brand provide for 3VA2163-5JQ36-0AA0?

Siemens provides RoHS and REACH declarations, plus IEC 60947-2 test certificates and UL listing documentation for the SENTRON 3VA series. Specific certificates are available on request.

MPN
3VA2163-5JQ36-0AA0