Skip to main content
Siemens 3VA2163-5KP32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5KP32-0DA0 SENTRON MCCB, 63 A, 121 kA at 415

MPN3VA2163-5KP32-0DA0

Siemens SENTRON 3VA2163-5KP32-0DA0, molded case circuit breaker, 3-pole, 63 A, 121 kA at 415 V, line protection, undervoltage release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5KP32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635KP320AA0

Ratings

3VA2163-5KP32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.6.5 W

Protection & Trip Unit

3VA2163-5KP32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-5KP32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5KP32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2163-5KP32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5KP32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what it does

The Siemens SENTRON 3VA2163-5KP32-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 63 A across the full ambient range from 40 °C to 70 °C — no derating needed in a warm panel. Its interrupting capacity hits 121 kA at 415 V and 187 kA at 240 V, so it handles high-fault utility feeds without cascading upstream — a key spec for main breaker or high-SCCR panel positions. The breaker includes an undervoltage release (UVR) and a communication function, making it suitable for remote tripping and status monitoring in automated distribution schemes.

Panel fit and integration

Dimensions are 105 mm wide, 181 mm tall, and 86 mm deep — a standard SENTRON 3VA2 frame that fits existing DIN-rail or panel-mount cutouts without rework. Rated insulation voltage of 800 V gives headroom for 690 V systems; the breaker carries a 6.5 W maximum power loss, manageable in a ventilated enclosure.

Breaking capacity across voltages

Interrupting ratings: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the 690 V figure is low, so verify coordination if that voltage is in play.

Frequently asked questions

What is the depth of 3VA2163-5KP32-0DA0?

Listed depth is 86 mm (3.39 in).

MPN
3VA2163-5KP32-0DA0